MOD1001-MBus
Integrates water, heat and other meter data into Modbus systems. Configure the MBus wiring, acquisition driver and supply for the selected edition. Select the matching hardware edition below.
Find the right connection between field interfaces and system protocols.
Filters use documented product information. Unspecified capabilities are excluded. Confirm protocol roles, device models, point counts and site conditions before ordering.
Select a condition to remove it. Multiple protocols still require an AND match.

Integrates water, heat and other meter data into Modbus systems. Configure the MBus wiring, acquisition driver and supply for the selected edition. Select the matching hardware edition below.

Exposes field-device data through Modbus interfaces for PLCs, HMI software or other Modbus clients, bringing different devices into a common data interface. Provides 2 Ethernet ports, 4 serial ports, 1024-point capacity. Acquisition covers more than 500 protocols; check the driver against each connected device.

Exposes field-device data through Modbus interfaces for PLCs, HMI software or other Modbus clients, bringing different devices into a common data interface. Provides 1 Ethernet port, 2 serial ports, 512-point capacity. Acquisition protocols: Modbus, BACnet; a Simulator driver is also included.

Integrates water, heat and other meter data into Modbus systems. Configure the MBus wiring, acquisition driver and supply for the selected edition. Provides 1 Ethernet port, 1 serial port, 1 two-wire MBus port. Select the matching hardware edition below.

Exposes field-device data through Modbus interfaces for PLCs, HMI software or other Modbus clients, bringing different devices into a common data interface. Provides 2 Ethernet ports, 4 serial ports, 1024-point capacity. Acquisition covers more than 500 protocols; check the driver against each connected device.

Exposes field-device data through Modbus interfaces for PLCs, HMI software or other Modbus clients, bringing different devices into a common data interface. Provides 1 Ethernet port, 2 serial ports, 512-point capacity. Acquisition covers more than 500 protocols; check the driver against each connected device.

Exposes field-device data through Modbus interfaces for PLCs, HMI software or other Modbus clients, bringing different devices into a common data interface. Provides 1 Ethernet port, 1 serial port, 256-point capacity. Acquisition protocols: Modbus, BACnet; a Simulator driver is also included.
Exposes field-device data through Modbus interfaces for PLCs, HMI software or other Modbus clients, bringing different devices into a common data interface. Provides 1 Ethernet port, 4 serial ports, 1024-point capacity. Acquisition protocols: Modbus, BACnet; a Simulator driver is also included.
Exposes field-device data through Modbus interfaces for PLCs, HMI software or other Modbus clients, bringing different devices into a common data interface. Provides 1 Ethernet port, 6 serial ports, 1536-point capacity. Acquisition covers more than 500 protocols; check the driver against each connected device.

Integrates water, heat and other meter data into Modbus systems. Configure the MBus wiring, acquisition driver and supply for the selected edition. Provides 1 Ethernet port, 1 two-wire MBus port. Select the matching hardware edition below.

Transparently connects Modbus RTU serial buses to a Modbus TCP network without per-point mapping; clients distinguish buses and devices by port and station address. Provides 1 Ethernet port, 2 serial ports. Acquisition protocols: Modbus RTU.

Exposes field-device data through Modbus interfaces for PLCs, HMI software or other Modbus clients, bringing different devices into a common data interface. Provides 2 Ethernet ports, 4 serial ports, 1024-point capacity. Acquisition protocols: Modbus, BACnet; a Simulator driver is also included.