Find the right connection between field interfaces and system protocols.

PRODUCT FINDER

Find your connection

Select multiple protocols or enter your own. Results must meet every selected requirement.

01 / Device / acquisition protocol
Select protocols · multiple
A–Z order · Search keeps list numbers

Names are from the supplied acquisition protocol list.

Showing all 579 protocols

02 / System / forwarding protocol
Select protocols · multiple
A–Z order · Search keeps list numbers

Names are from documented product forwarding protocols.

Showing all 19 protocols

Select physical interfaces separately from acquisition protocols. CAN, KNX TP and two-wire MBus ports have independent counts; protocol support does not establish a physical port.

DDC I/O and touchscreenRefine by product type

When a touchscreen is required, results must have a built-in touchscreen and meet all I/O counts. Otherwise, positive I/O counts select DDC controllers. Counts are minimum requirements. HMI configuration support does not imply a built-in screen.

Power and wireless connectivityAdditional requirements

Checked requirements match only confirmed capabilities. Review product notes for optional modules, shared ports and power conditions.

Filters use documented product information. Unspecified capabilities are excluded. Confirm protocol roles, device models, point counts and site conditions before ordering.

35 results

Current selection conditions

Select a condition to remove it. Multiple protocols still require an AND match.

MOD1002-ARM(NXP)
Modbus Gateway

MOD1002-ARM(NXP)

Exposes field-device data through Modbus interfaces for PLCs, HMI software or other Modbus clients, bringing different devices into a common data interface. Provides 1 Ethernet port, 2 serial ports, 512-point capacity. Acquisition covers more than 500 protocols; check the driver against each connected device. This model supports Type-C power. This page covers the NXP edition.

RS485 ports2 portsRS232 ports0Ethernet ports1 portsSerial ports2 ports
Modbus RTUModbus TCPOPC UA
MOD2004-ARM(OPC)
Modbus Gateway

MOD2004-ARM(OPC)

Exposes field-device data through Modbus interfaces for PLCs, HMI software or other Modbus clients, bringing different devices into a common data interface. Provides 2 Ethernet ports, 4 serial ports, 1024-point capacity. Acquisition covers more than 500 protocols; check the driver against each connected device. This edition also supports OPC DA acquisition.

RS485 ports4 portsRS232 ports0Ethernet ports2 portsSerial ports4 ports
Modbus RTUModbus TCPOPC UA