SUNFULL / PRODUCTS

Products

Find the right connection between field interfaces and system protocols.

PRODUCT FINDER

Find your connection

Select multiple protocols or enter your own. Results must meet every selected requirement.

01 / Device / acquisition protocol
1 selected
A–Z order · Search keeps list numbers

Names are from the supplied acquisition protocol list.

Showing all 579 protocols

Modbus RTU
02 / System / forwarding protocol
Select protocols · multiple
A–Z order · Search keeps list numbers

Choose forwarding protocols or database integration. Support depends on the model documentation.

Showing all 20 protocols

Select physical interfaces separately from acquisition protocols. CAN, KNX TP and two-wire MBus ports have independent counts; protocol support does not establish a physical port. USB Type-C includes power connectors; check each model's documentation for data communication support.

DDC I/O and touchscreenRefine by product type

When a touchscreen is required, results must have a built-in touchscreen and meet all I/O counts. Otherwise, positive I/O counts select DDC controllers. Counts are minimum requirements. HMI configuration support does not imply a built-in screen.

Power and wireless connectivityAdditional requirements

Checked requirements match only confirmed capabilities. Review product notes for optional modules, shared ports and power conditions.

Filters use documented product information. Unspecified capabilities are excluded. Confirm protocol roles, device models, point counts and site conditions before ordering.

13 results

Current selection conditions

Select a condition to remove it. Multiple protocols still require an AND match.

HMI1002-ARM(LoRaWAN)
HMI / web visualization gateways

HMI1002-ARM(LoRaWAN)

An indoor LoRaWAN gateway linking wireless-node data to Ethernet and web monitoring for settings such as offices or campuses. Select an operating band matching the end devices. Provides 1 Ethernet port, 2 serial ports, 512-point capacity. Acquisition covers more than 500 protocols; check the driver against each connected device. This model supports WiFi. This model supports Type-C power.

RS485 ports2 portsRS232 ports—Ethernet ports1 portsSerial ports2 ports
HMI configurationAll acquisition protocols for serial and Ethernet connectionsBACnetModbusMQTTDatabase
Why this matches
  • Acquisition protocolsModbus RTU

Confirm communication roles, capacity and installation conditions.

HMI1002-ARM
HMI / web visualization gateways

HMI1002-ARM

Browser-based HMI monitoring for building and industrial equipment, with 1 Ethernet port, 2 serial ports, 512 points and up to 64 devices. Connect the collected data to supervisory systems through BACnet/IP, BACnet MS/TP, Modbus, MQTT or OPC UA.

RS485 ports2 portsRS232 ports—Ethernet ports1 portsSerial ports2 ports
HMI configurationAll acquisition protocols for serial and Ethernet connectionsBACnet/IPBACnet MS/TPModbusDatabase
Why this matches
  • Acquisition protocolsModbus RTU

Confirm communication roles, capacity and installation conditions.

HMI1002-LITE-4G
HMI / web visualization gateways

HMI1002-LITE-4G

Organizes field-device data into browser-based HMI screens for building or industrial monitoring and provides interfaces for other supervisory systems. Provides 1 Ethernet port, 2 serial ports, 512-point capacity. Acquisition is limited to the OPC, Modbus and BACnet protocol families. This model supports 4G.

RS485 ports2 portsRS232 ports—Ethernet ports1 portsSerial ports2 ports
HMI configurationListed protocol families · OPC / Modbus / BACnetBACnetModbusMQTTDatabase
Why this matches
  • Acquisition protocolsModbus RTU

Confirm communication roles, capacity and installation conditions.

HMI1002-ARM(CAN)
HMI / web visualization gateways

HMI1002-ARM(CAN)

Collects data through native CAN buses and uses X2View for browser-based monitoring and supervisory integration. CAN ports are distinct from RS485 serial ports. Provides 1 Ethernet port, 2 CAN ports, 512-point capacity. Acquisition covers all serial and Ethernet protocols in the reviewed list. Existing explicit support for CAN is retained.

RS485 ports—RS232 ports—Ethernet ports1 portsSerial ports—CAN ports2 ports
HMI configurationAll acquisition protocols for serial and Ethernet connectionsBACnetModbusMQTTDatabase
Why this matches
  • Acquisition protocolsModbus RTU

Confirm communication roles, capacity and installation conditions.

HMI1002-ARM(NXP)
HMI / web visualization gateways

HMI1002-ARM(NXP)

Organizes field-device data into browser-based HMI screens for building or industrial monitoring and provides interfaces for other supervisory systems. Provides 1 Ethernet port, 2 serial ports, 512-point capacity. Acquisition covers more than 500 protocols; check the driver against each connected device. This model supports Type-C power. This page covers the NXP edition.

RS485 ports2 portsRS232 ports—Ethernet ports1 portsSerial ports2 ports
HMI configurationAll acquisition protocols for serial and Ethernet connectionsBACnetModbusMQTTDatabase
Why this matches
  • Acquisition protocolsModbus RTU

Confirm communication roles, capacity and installation conditions.

HMI1002-Lite-E(4G)
HMI / web visualization gateways

HMI1002-Lite-E(4G)

Supports field-data acquisition and MQTT integration, with acquisition and forwarding configured from the device point list to connect serial devices to supervisory platforms. Provides 1 Ethernet port, 2 serial ports, 512-point capacity. Acquisition is limited to Modbus RTU. This model supports 4G.

RS485 ports2 portsRS232 ports—Ethernet ports1 portsSerial ports2 ports
Listed protocols · Modbus RTUBACnetModbusMQTT
Why this matches
  • Acquisition protocolsModbus RTU

Confirm communication roles, capacity and installation conditions.

HMI1002-Lite(NXP)
HMI / web visualization gateways

HMI1002-Lite(NXP)

Organizes field-device data into browser-based HMI screens for building or industrial monitoring and provides interfaces for other supervisory systems. Provides 1 Ethernet port, 2 serial ports, 512-point capacity. Acquisition is limited to the OPC, Modbus and BACnet protocol families. This model supports Type-C power. This page covers the NXP edition.

RS485 ports2 portsRS232 ports—Ethernet ports1 portsSerial ports2 ports
HMI configurationListed protocol families · OPC / Modbus / BACnetBACnetModbusMQTTDatabase
Why this matches
  • Acquisition protocolsModbus RTU

Confirm communication roles, capacity and installation conditions.

HMI1002-Lite-E
HMI / web visualization gateways

HMI1002-Lite-E

Collect Modbus RTU device data using 1 Ethernet port, 2 RS485 ports and a 512-point capacity. Connect field devices to BACnet or Modbus supervisory systems and use the gateway’s MQTT service for building or industrial monitoring applications.

RS485 ports2 portsRS232 ports—Ethernet ports1 portsSerial ports2 ports
Listed protocols · Modbus RTUBACnetModbusMQTT
Why this matches
  • Acquisition protocolsModbus RTU

Confirm communication roles, capacity and installation conditions.

HMI1002-ARM-4G
HMI / web visualization gateways

HMI1002-ARM-4G

Organizes field-device data into browser-based HMI screens for building or industrial monitoring and provides interfaces for other supervisory systems. Provides 1 Ethernet port, 2 serial ports, 512-point capacity. Acquisition covers more than 500 protocols; check the driver against each connected device. This model supports 4G.

RS485 ports2 portsRS232 ports—Ethernet ports1 portsSerial ports2 ports
HMI configurationAll acquisition protocols for serial and Ethernet connectionsBACnetModbusMQTTDatabase
Why this matches
  • Acquisition protocolsModbus RTU

Confirm communication roles, capacity and installation conditions.

HMI1002-Lite
HMI / web visualization gateways

HMI1002-Lite

Organizes field-device data into browser-based HMI screens for building or industrial monitoring and provides interfaces for other supervisory systems. Provides 1 Ethernet port, 2 serial ports, 512-point capacity. Acquisition is limited to the OPC, Modbus and BACnet protocol families.

RS485 ports2 portsRS232 ports—Ethernet ports1 portsSerial ports2 ports
HMI configurationListed protocol families · OPC / Modbus / BACnetBACnet/IPBACnetModbusDatabase
Why this matches
  • Acquisition protocolsModbus RTU

Confirm communication roles, capacity and installation conditions.

HMI1002-Lite-E(WiFi)
HMI / web visualization gateways

HMI1002-Lite-E(WiFi)

Supports field-data acquisition and MQTT integration, with acquisition and forwarding configured from the device point list to connect serial devices to supervisory platforms. Provides 1 Ethernet port, 2 serial ports, 512-point capacity. Acquisition is limited to Modbus RTU. This model supports WiFi.

RS485 ports2 portsRS232 ports—Ethernet ports1 portsSerial ports2 ports
Listed protocols · Modbus RTUBACnetModbusMQTT
Why this matches
  • Acquisition protocolsModbus RTU

Confirm communication roles, capacity and installation conditions.

HMI1002-Lite-WiFi
HMI / web visualization gateways

HMI1002-Lite-WiFi

Organizes field-device data into browser-based HMI screens for building or industrial monitoring and provides interfaces for other supervisory systems. Provides 1 Ethernet port, 2 serial ports, 512-point capacity. Acquisition is limited to the OPC, Modbus and BACnet protocol families. This model supports WiFi.

RS485 ports2 portsRS232 ports—Ethernet ports1 portsSerial ports2 ports
HMI configurationListed protocol families · OPC / Modbus / BACnetBACnetModbusMQTTDatabase
Why this matches
  • Acquisition protocolsModbus RTU

Confirm communication roles, capacity and installation conditions.