SUNFULL / PRODUCTS

Products

Find the right connection between field interfaces and system protocols.

PRODUCT FINDER

Find your connection

Select multiple protocols or enter your own. Results must meet every selected requirement.

01 / Device / acquisition protocol
Select protocols · multiple
A–Z order · Search keeps list numbers

Names are from the supplied acquisition protocol list.

Showing all 579 protocols

02 / System / forwarding protocol
1 selected
A–Z order · Search keeps list numbers

Choose forwarding protocols or database integration. Support depends on the model documentation.

Showing all 20 protocols

Database

Select physical interfaces separately from acquisition protocols. CAN, KNX TP and two-wire MBus ports have independent counts; protocol support does not establish a physical port. USB Type-C includes power connectors; check each model's documentation for data communication support.

DDC I/O and touchscreenRefine by product type

When a touchscreen is required, results must have a built-in touchscreen and meet all I/O counts. Otherwise, positive I/O counts select DDC controllers. Counts are minimum requirements. HMI configuration support does not imply a built-in screen.

Power and wireless connectivityAdditional requirements

Checked requirements match only confirmed capabilities. Review product notes for optional modules, shared ports and power conditions.

Filters use documented product information. Unspecified capabilities are excluded. Confirm protocol roles, device models, point counts and site conditions before ordering.

58 results

Current selection conditions

Select a condition to remove it. Multiple protocols still require an AND match.

HMI1004-Lite
Web configuration gateways

HMI1004-Lite

Organizes field-device data into browser-based HMI screens for building or industrial monitoring and provides interfaces for other supervisory systems. Provides 1 Ethernet port, 4 serial ports, 1024-point capacity. Acquisition protocols: Modbus, BACnet; a Simulator driver is also included.

RS485 ports4 portsRS232 ports—Ethernet ports1 portsSerial ports4 ports
HMI configurationBACnetModbusMQTTDatabase
Why this matches
  • Forwarding protocolsDatabase

Confirm communication roles, capacity and installation conditions.

HMI1302-ARM-4G
Web configuration gateways

HMI1302-ARM-4G

Organizes field-device data into browser-based HMI screens for building or industrial monitoring and provides interfaces for other supervisory systems. Provides 1 Ethernet port, 2 serial ports, 512-point capacity. Acquisition covers more than 500 protocols; check the driver against each connected device. This model supports 4G. This is a custom edition; confirm the delivery configuration against its own document.

RS485 ports2 portsRS232 ports—Ethernet ports1 portsSerial ports2 ports
HMI configurationAll acquisition protocols for serial and Ethernet connectionsBACnetModbusMQTTDatabase
Why this matches
  • Forwarding protocolsDatabase

Confirm communication roles, capacity and installation conditions.

HMI1001-Lite
Web configuration gateways

HMI1001-Lite

Organizes field-device data into browser-based HMI screens for building or industrial monitoring and provides interfaces for other supervisory systems. Provides 1 Ethernet port, 1 serial port, 256-point capacity. Acquisition protocols: Modbus, BACnet; a Simulator driver is also included.

RS485 ports1 portsRS232 ports—Ethernet ports1 portsSerial ports1 ports
HMI configurationBACnetModbusMQTTDatabase
Why this matches
  • Forwarding protocolsDatabase

Confirm communication roles, capacity and installation conditions.

HMI1004-ARM
Web configuration gateways

HMI1004-ARM

Organizes field-device data into browser-based HMI screens for building or industrial monitoring and provides interfaces for other supervisory systems. Provides 1 Ethernet port, 4 serial ports, 1024-point capacity. Acquisition covers more than 500 protocols; check the driver against each connected device.

RS485 ports4 portsRS232 ports—Ethernet ports1 portsSerial ports4 ports
HMI configurationAll acquisition protocols for serial and Ethernet connectionsBACnetModbusMQTTDatabase
Why this matches
  • Forwarding protocolsDatabase

Confirm communication roles, capacity and installation conditions.

HMI1002-Lite-WiFi
Web configuration gateways

HMI1002-Lite-WiFi

Organizes field-device data into browser-based HMI screens for building or industrial monitoring and provides interfaces for other supervisory systems. Provides 1 Ethernet port, 2 serial ports, 512-point capacity. Acquisition is limited to the OPC, Modbus and BACnet protocol families. This model supports WiFi.

RS485 ports2 portsRS232 ports—Ethernet ports1 portsSerial ports2 ports
HMI configurationListed protocol families · OPC / Modbus / BACnetBACnetModbusMQTTDatabase
Why this matches
  • Forwarding protocolsDatabase

Confirm communication roles, capacity and installation conditions.

HMI1302-ARM
Web configuration gateways

HMI1302-ARM

Organizes field-device data into browser-based HMI screens for building or industrial monitoring and provides interfaces for other supervisory systems. Provides 1 Ethernet port, 2 serial ports, 512-point capacity. Acquisition covers more than 500 protocols; check the driver against each connected device. This is a custom edition; confirm the delivery configuration against its own document.

RS485 ports2 portsRS232 ports—Ethernet ports1 portsSerial ports2 ports
HMI configurationAll acquisition protocols for serial and Ethernet connectionsBACnetModbusMQTTDatabase
Why this matches
  • Forwarding protocolsDatabase

Confirm communication roles, capacity and installation conditions.

HMI1002-ARM-WiFi
Web configuration gateways

HMI1002-ARM-WiFi

Organizes field-device data into browser-based HMI screens for building or industrial monitoring and provides interfaces for other supervisory systems. Provides 1 Ethernet port, 2 serial ports, 512-point capacity. Acquisition covers more than 500 protocols; check the driver against each connected device. This model supports WiFi.

RS485 ports2 portsRS232 ports—Ethernet ports1 portsSerial ports2 ports
HMI configurationAll acquisition protocols for serial and Ethernet connectionsBACnetModbusMQTTDatabase
Why this matches
  • Forwarding protocolsDatabase

Confirm communication roles, capacity and installation conditions.

HMI1001-ARM
Web configuration gateways

HMI1001-ARM

Organizes field-device data into browser-based HMI screens for building or industrial monitoring and provides interfaces for other supervisory systems. Provides 1 Ethernet port, 1 serial port, 256-point capacity. Acquisition covers more than 500 protocols; check the driver against each connected device.

RS485 ports1 portsRS232 ports—Ethernet ports1 portsSerial ports1 ports
HMI configurationAll acquisition protocols for serial and Ethernet connectionsBACnetModbusMQTTDatabase
Why this matches
  • Forwarding protocolsDatabase

Confirm communication roles, capacity and installation conditions.