Connect devices. Unlock data.sales@opcmaster.com / +86 21 58776098
SUNFULL / PRODUCTS

Products

Find the right connection between field interfaces and system protocols.

PRODUCT FINDER

Find your connection

Select multiple protocols or enter your own. Results must meet every selected requirement.

01 / Device / acquisition protocol
Select protocols · multiple
A–Z order · Search keeps list numbers

Names are from the supplied acquisition protocol list.

Showing all 579 protocols

02 / System / forwarding protocol
1 selected
A–Z order · Search keeps list numbers

Names are from documented product forwarding protocols.

Showing all 19 protocols

OPC UA

Select physical interfaces separately from acquisition protocols. CAN, KNX TP and two-wire MBus ports have independent counts; protocol support does not establish a physical port.

DDC I/O and touchscreenRefine by product type

When a touchscreen is required, results must have a built-in touchscreen and meet all I/O counts. Otherwise, positive I/O counts select DDC controllers. Counts are minimum requirements. HMI configuration support does not imply a built-in screen.

Power and wireless connectivityAdditional requirements

Checked requirements match only confirmed capabilities. Review product notes for optional modules, shared ports and power conditions.

Filters use documented product information. Unspecified capabilities are excluded. Confirm protocol roles, device models, point counts and site conditions before ordering.

164 results

Current selection conditions

Select a condition to remove it. Multiple protocols still require an AND match.

HMI2000-ARM-E
HMI Gateway

HMI2000-ARM-E

Organizes field-device data into browser-based HMI screens for building or industrial monitoring and provides interfaces for other supervisory systems. Provides 2 Ethernet ports, 512-point capacity. Acquisition covers more than 500 protocols; check the driver against each connected device.

RS485 ports0RS232 ports0Ethernet ports2 portsSerial ports0
HMI configurationBACnet/IPModbus TCPMQTT
Why this matches
  • Forwarding protocolsOPC UA

Confirm communication roles, capacity and installation conditions.

HMI2004-A9(OPC)
HMI Gateway

HMI2004-A9(OPC)

Organizes field-device data into browser-based HMI screens for building or industrial monitoring and provides interfaces for other supervisory systems. Provides 2 Ethernet ports, 4 serial ports, 2048-point capacity. Acquisition covers more than 500 protocols; check the driver against each connected device. This edition also supports OPC DA acquisition.

RS485 ports4 portsRS232 ports0Ethernet ports2 portsSerial ports4 ports
HMI configurationBACnetModbusMQTT
Why this matches
  • Forwarding protocolsOPC UA

Confirm communication roles, capacity and installation conditions.

BAC2304-Lite
Customized products

BAC2304-Lite

Converts field-controller and meter data into BACnet interfaces for point-list-based integration with building management systems. Provides 2 Ethernet ports, 4 serial ports, 1024-point capacity. Acquisition protocols: Modbus, BACnet; a Simulator driver is also included. This is a custom edition; confirm the delivery configuration against its own document.

RS485 ports4 portsRS232 ports0Ethernet ports2 portsSerial ports4 ports
Listed protocols · Simulator / Modbus / BACnetBACnet/IPBACnet MS/TPOPC UA
Why this matches
  • Forwarding protocolsOPC UA

Confirm communication roles, capacity and installation conditions.

HMI2004-EMS-4G
EMS

HMI2004-EMS-4G

Collects, bills, stores and classifies water, electricity, gas and heating/cooling energy data, with time-of-use electricity records and charts for reviewing building or equipment consumption. Provides 2 Ethernet ports, 4 serial ports, 2048-point capacity. Acquisition covers more than 500 protocols; check the driver against each connected device. This model supports 4G.

RS485 ports0RS232 ports0Ethernet ports2 portsSerial ports4 ports
BACnetModbusMQTT
Why this matches
  • Forwarding protocolsOPC UA

Confirm communication roles, capacity and installation conditions.

KNX2004-ARM
KNX Gateway

KNX2004-ARM

Integrates lighting and control-device data into KNX IP systems, with the documented logic and timing functions for lighting scenes. Check KNX IP and the physical KNX TP bus separately. Provides 2 Ethernet ports, 4 serial ports, 1024-point capacity. Acquisition covers more than 500 protocols; check the driver against each connected device.

RS485 ports4 portsRS232 ports0Ethernet ports2 portsSerial ports4 ports
KNX IPOPC UA
Why this matches
  • Forwarding protocolsOPC UA

Confirm communication roles, capacity and installation conditions.

BAC1008-Lite-E
BACnet Router

BAC1008-Lite-E

Converts field-controller and meter data into BACnet interfaces for point-list-based integration with building management systems. Provides 1 Ethernet port, 8 serial ports, 2048-point capacity. Acquisition protocols: Modbus RTU; a Simulator driver is also included.

RS485 ports8 portsRS232 ports0Ethernet ports1 portsSerial ports8 ports
Listed protocols · Modbus RTU / SimulatorBACnet/IPBACnet MS/TPOPC UA
Why this matches
  • Forwarding protocolsOPC UA

Confirm communication roles, capacity and installation conditions.

HMI1006-Lite-E
HMI Gateway

HMI1006-Lite-E

Supports field-data acquisition and MQTT integration, with acquisition and forwarding configured from the device point list to connect serial or network devices to supervisory platforms. Provides 1 Ethernet port, 6 serial ports, 1536-point capacity. Acquisition protocols: Modbus RTU, Modbus TCP; a Simulator driver is also included.

RS485 ports6 portsRS232 ports0Ethernet ports1 portsSerial ports6 ports
Listed protocols · Modbus RTU / Modbus TCP / SimulatorBACnetModbusMQTT
Why this matches
  • Forwarding protocolsOPC UA

Confirm communication roles, capacity and installation conditions.

HMI1001-Lite-E(WiFi)
HMI Gateway

HMI1001-Lite-E(WiFi)

Supports field-data acquisition and MQTT integration, with acquisition and forwarding configured from the device point list to connect serial or network devices to supervisory platforms. Provides 1 Ethernet port, 1 serial port, 256-point capacity. Acquisition protocols: Modbus RTU, Modbus TCP; a Simulator driver is also included. This model supports WiFi.

RS485 ports1 portsRS232 ports0Ethernet ports1 portsSerial ports1 ports
Listed protocols · Modbus RTU / Modbus TCP / SimulatorBACnetModbusMQTT
Why this matches
  • Forwarding protocolsOPC UA

Confirm communication roles, capacity and installation conditions.

MOD2004-Lite
Modbus Gateway

MOD2004-Lite

Exposes field-device data through Modbus interfaces for PLCs, HMI software or other Modbus clients, bringing different devices into a common data interface. Provides 2 Ethernet ports, 4 serial ports, 1024-point capacity. Acquisition protocols: Modbus, BACnet; a Simulator driver is also included.

RS485 ports4 portsRS232 ports0Ethernet ports2 portsSerial ports4 ports
Listed protocols · Simulator / Modbus / BACnetModbus RTUModbus TCPOPC UA
Why this matches
  • Forwarding protocolsOPC UA

Confirm communication roles, capacity and installation conditions.

KNX1002-ARM
KNX Gateway

KNX1002-ARM

Integrates lighting and control-device data into KNX IP systems, with the documented logic and timing functions for lighting scenes. Check KNX IP and the physical KNX TP bus separately. Provides 1 Ethernet port, 2 serial ports, 512-point capacity. Acquisition covers more than 500 protocols; check the driver against each connected device. This model supports Type-C power.

RS485 ports2 portsRS232 ports0Ethernet ports1 portsSerial ports2 ports
KNX IPOPC UA
Why this matches
  • Forwarding protocolsOPC UA

Confirm communication roles, capacity and installation conditions.

BAC2004-ARM-SC
BACnet Router

BAC2004-ARM-SC

Integrates field-device data into BACnet/SC secure-communication networks, with BACnet MS/TP and OPC UA interfaces for building projects requiring BACnet/SC integration. Provides 2 Ethernet ports, 4 serial ports, 1024-point capacity. Acquisition covers more than 500 protocols; check the driver against each connected device.

RS485 ports4 portsRS232 ports0Ethernet ports2 portsSerial ports4 ports
BACnet MS/TPBACnet/SCOPC UA
Why this matches
  • Forwarding protocolsOPC UA

Confirm communication roles, capacity and installation conditions.

MOD1002-ARM(NXP)
Modbus Gateway

MOD1002-ARM(NXP)

Exposes field-device data through Modbus interfaces for PLCs, HMI software or other Modbus clients, bringing different devices into a common data interface. Provides 1 Ethernet port, 2 serial ports, 512-point capacity. Acquisition covers more than 500 protocols; check the driver against each connected device. This model supports Type-C power. This page covers the NXP edition.

RS485 ports2 portsRS232 ports0Ethernet ports1 portsSerial ports2 ports
Modbus RTUModbus TCPOPC UA
Why this matches
  • Forwarding protocolsOPC UA

Confirm communication roles, capacity and installation conditions.