SUNFULL / PRODUCT GUIDE

Compare models in a series

Explore model variants side by side. Compare acquisition scope, forwarding protocols and physical ports, then open a model for its full specifications and documents.

Select by requirements

5 matching models · 219 in the catalog

Showing 1–4 of 5
How to choose within a series

Choose for your project

Match device-side protocols and the host system first, then check ports, wireless connections and capacity. Candidates below use confirmed model specifications.

You need multiple serial and Ethernet protocols

Check models confirmed to cover all acquisition protocols for serial and Ethernet connections. Check protocol scope and physical port counts separately. Confirm dedicated CAN, KNX TP and 2-wire MBus connections for the specific model.

Confirmed candidates1 models
  • HMI1004-ARM(EMS)

    All serial and Ethernet acquisition protocols

    Forwarding: BACnet / Modbus / MQTT / OPC UA

View full group specifications

Acquisition scope needs confirmation

These models have no listed acquisition scope suitable for this decision. Check their model notes and provide device make, model and protocol documentation.

Models to verify4 models
Show 1 more models
  • HMI2006-EMS

    Acquisition scope unconfirmed

    Forwarding: BACnet / Modbus / MQTT / OPC UA

View full group specifications

This guidance narrows the candidates. Confirm communication roles, read/write direction, the point list, wiring and model-specific resources before final selection.

“Unconfirmed” means documentation does not establish a value; it does not mean zero or unsupported.

Compare models in a series
ModelDevice acquisition → System forwarding
HMI1004-ARM(EMS)
HMI2000-EMS
SUNFULL
HMI2004-EMS-4G
HMI2004-EMS(RK3568)
01Acquisition scopeDevice side
All acquisition protocols for serial and Ethernet connections
—
—
—
02Forwarding protocolsSystem side
BACnetModbusMQTTOPC UA
BACnet/IPModbus TCPMQTTOPC UA
BACnetModbusMQTTOPC UA
BACnetModbusMQTTOPC UA
Point capacity1024204820482048
Device capacity128—128128
Ethernet ports1222
Total serial ports4—44
RS4854——4
RS232————
CAN ports————
KNX TP ports————
Two-wire MBus ports————
DI channels————
DO channels————
AI channels————
AO channels————
Touchscreen————
Model documents
Port and model notes

More than 500 protocols.

Specifications & downloads
Port and model notes

More than 500 protocols.

Specifications & downloads
Port and model notes

More than 500 protocols.

Specifications & downloads
Port and model notes

More than 500 protocols.

Specifications & downloads
HMI1004-ARM(EMS)

01Acquisition scopeDevice side

All acquisition protocols for serial and Ethernet connections

02Forwarding protocolsSystem side

BACnetModbusMQTTOPC UA
Point capacity
1024
Device capacity
128
Ethernet ports
1
Total serial ports
4
RS485
4
RS232
—
CAN ports
—
KNX TP ports
—
Two-wire MBus ports
—
DI channels
—
DO channels
—
AI channels
—
AO channels
—
Touchscreen
—
Port and model notes

More than 500 protocols.

Specifications & downloads
HMI2000-EMS

01Acquisition scopeDevice side

—

02Forwarding protocolsSystem side

BACnet/IPModbus TCPMQTTOPC UA
Point capacity
2048
Device capacity
—
Ethernet ports
2
Total serial ports
—
RS485
—
RS232
—
CAN ports
—
KNX TP ports
—
Two-wire MBus ports
—
DI channels
—
DO channels
—
AI channels
—
AO channels
—
Touchscreen
—
Port and model notes

More than 500 protocols.

Specifications & downloads
SUNFULL
HMI2004-EMS-4G

01Acquisition scopeDevice side

—

02Forwarding protocolsSystem side

BACnetModbusMQTTOPC UA
Point capacity
2048
Device capacity
128
Ethernet ports
2
Total serial ports
4
RS485
—
RS232
—
CAN ports
—
KNX TP ports
—
Two-wire MBus ports
—
DI channels
—
DO channels
—
AI channels
—
AO channels
—
Touchscreen
—
Port and model notes

More than 500 protocols.

Specifications & downloads
HMI2004-EMS(RK3568)

01Acquisition scopeDevice side

—

02Forwarding protocolsSystem side

BACnetModbusMQTTOPC UA
Point capacity
2048
Device capacity
128
Ethernet ports
2
Total serial ports
4
RS485
4
RS232
—
CAN ports
—
KNX TP ports
—
Two-wire MBus ports
—
DI channels
—
DO channels
—
AI channels
—
AO channels
—
Touchscreen
—
Port and model notes

More than 500 protocols.

Specifications & downloads

“—” means the documentation does not establish a value; 0 is a confirmed zero. Check model documentation for shared ports, options and protocol roles.