SUNFULL / PRODUCT GUIDE

Compare models in a series

Explore model variants side by side. Compare acquisition scope, forwarding protocols and physical ports, then open a model for its full specifications and documents.

Select by requirements

3 matching models · 219 in the catalog

Showing 1–3 of 3
How to choose within a series

Choose for your project

Match device-side protocols and the host system first, then check ports, wireless connections and capacity. Candidates below use confirmed model specifications.

You need multiple serial and Ethernet protocols

Check models confirmed to cover all acquisition protocols for serial and Ethernet connections. Check protocol scope and physical port counts separately. Confirm dedicated CAN, KNX TP and 2-wire MBus connections for the specific model.

Confirmed candidates1 models
  • HMI1004-ARM(Scada)

    All serial and Ethernet acquisition protocols

    Forwarding: BACnet / Modbus / MQTT / Database / OPC UA

View full group specifications

The device protocol is fixed

Check each model’s listed acquisition protocols and the required host-system protocol. A model suffix alone does not establish equivalent acquisition capability.

Confirmed candidates2 models
  • HMI2000-Scada

    Listed acquisition protocols: OPC UA / OPC XML-DA / OPC DA / BACnet/IP / Modbus TCP / Siemens S7 / EtherNet/IP / SNMP

    Forwarding: BACnet/IP / Modbus TCP / MQTT / Database / OPC UA

  • HMI2004-Scada(RK3568)

    Listed acquisition protocols: OPC UA / OPC XML-DA / OPC DA / BACnet/IP / Modbus TCP / Siemens S7 / EtherNet/IP / SNMP

    Forwarding: BACnet / Modbus / MQTT / Database / OPC UA

View full group specifications

This guidance narrows the candidates. Confirm communication roles, read/write direction, the point list, wiring and model-specific resources before final selection.

“Unconfirmed” means documentation does not establish a value; it does not mean zero or unsupported.

Compare models in a series
ModelDevice acquisition → System forwarding
HMI1004-ARM(Scada)
HMI2000-Scada
HMI2004-Scada(RK3568)
01Acquisition scopeDevice side
All acquisition protocols for serial and Ethernet connections
Listed acquisition protocols
OPC UAOPC XML-DAOPC DABACnet/IP
Show 5 more
Modbus TCPSiemens S7EtherNet/IPSNMPSimulator
Listed acquisition protocols
OPC UAOPC XML-DAOPC DABACnet/IP
Show 5 more
Modbus TCPSiemens S7EtherNet/IPSNMPSimulator
02Forwarding protocolsSystem side
BACnetModbusMQTTDatabase
Show 1 more
OPC UA
BACnet/IPModbus TCPMQTTDatabase
Show 1 more
OPC UA
BACnetModbusMQTTDatabase
Show 1 more
OPC UA
Point capacity102420482048
Device capacity128—128
Ethernet ports122
Total serial ports4—4
RS4854—4
RS232———
CAN ports———
KNX TP ports———
Two-wire MBus ports———
DI channels———
DO channels———
AI channels———
AO channels———
Touchscreen———
Model documents
Port and model notes

More than 500 protocols.

Specifications & downloads
Port and model notes

More than 500 protocols.

Specifications & downloads
Port and model notes

More than 500 protocols.

Specifications & downloads
HMI1004-ARM(Scada)

01Acquisition scopeDevice side

All acquisition protocols for serial and Ethernet connections

02Forwarding protocolsSystem side

BACnetModbusMQTTDatabase
Show 1 more
OPC UA
Point capacity
1024
Device capacity
128
Ethernet ports
1
Total serial ports
4
RS485
4
RS232
—
CAN ports
—
KNX TP ports
—
Two-wire MBus ports
—
DI channels
—
DO channels
—
AI channels
—
AO channels
—
Touchscreen
—
Port and model notes

More than 500 protocols.

Specifications & downloads
HMI2000-Scada

01Acquisition scopeDevice side

Listed acquisition protocols
OPC UAOPC XML-DAOPC DABACnet/IP
Show 5 more
Modbus TCPSiemens S7EtherNet/IPSNMPSimulator

02Forwarding protocolsSystem side

BACnet/IPModbus TCPMQTTDatabase
Show 1 more
OPC UA
Point capacity
2048
Device capacity
—
Ethernet ports
2
Total serial ports
—
RS485
—
RS232
—
CAN ports
—
KNX TP ports
—
Two-wire MBus ports
—
DI channels
—
DO channels
—
AI channels
—
AO channels
—
Touchscreen
—
Port and model notes

More than 500 protocols.

Specifications & downloads
HMI2004-Scada(RK3568)

01Acquisition scopeDevice side

Listed acquisition protocols
OPC UAOPC XML-DAOPC DABACnet/IP
Show 5 more
Modbus TCPSiemens S7EtherNet/IPSNMPSimulator

02Forwarding protocolsSystem side

BACnetModbusMQTTDatabase
Show 1 more
OPC UA
Point capacity
2048
Device capacity
128
Ethernet ports
2
Total serial ports
4
RS485
4
RS232
—
CAN ports
—
KNX TP ports
—
Two-wire MBus ports
—
DI channels
—
DO channels
—
AI channels
—
AO channels
—
Touchscreen
—
Port and model notes

More than 500 protocols.

Specifications & downloads

“—” means the documentation does not establish a value; 0 is a confirmed zero. Check model documentation for shared ports, options and protocol roles.