Explore model variants side by side. Compare acquisition scope, forwarding protocols and physical ports, then open a model for its full specifications and documents.
Match device-side protocols and the host system first, then check ports, wireless connections and capacity. Candidates below use confirmed model specifications.
You need multiple serial and Ethernet protocols
Check models confirmed to cover all acquisition protocols for serial and Ethernet connections. Check protocol scope and physical port counts separately. Confirm dedicated CAN, KNX TP and 2-wire MBus connections for the specific model.
This guidance narrows the candidates. Confirm communication roles, read/write direction, the point list, wiring and model-specific resources before final selection.
“Unconfirmed” means documentation does not establish a value; it does not mean zero or unsupported.
WiFi is an optional module; confirm it when ordering.
Confirmed common specifications: 1 Ethernet port, 2 serial ports, 512 points. Check the matching datasheet for power options and other edition-specific details.
Filters use only specifications explicitly shared by every hardware edition listed here. Check the matching document below for processor, power and other edition-specific differences.
All acquisition protocols for serial and Ethernet connections
02Forwarding protocolsSystem side
BACnetModbusMQTTDatabase
Show 1 more
OPC UA
Point capacity
512
Ethernet ports
1
Total serial ports
2
RS485
2
Touchscreen
Included
All specifications
0 means no such interface; — means the specification is unconfirmed.
Point capacity
512
Ethernet ports
1
Total serial ports
2
RS485
2
RS232
—
CAN ports
—
KNX TP ports
—
Two-wire MBus ports
—
DI channels
—
DO channels
—
AI channels
—
AO channels
—
Touchscreen
Included
Port and model notes
WiFi is an optional module; confirm it when ordering.
Confirmed common specifications: 1 Ethernet port, 2 serial ports, 512 points. Check the matching datasheet for power options and other edition-specific details.
All acquisition protocols for serial and Ethernet connections
02Forwarding protocolsSystem side
BACnetModbusMQTTDatabase
Show 1 more
OPC UA
Point capacity
2048
Ethernet ports
1
Total serial ports
2
RS485
2
Touchscreen
Included
All specifications
0 means no such interface; — means the specification is unconfirmed.
Point capacity
2048
Ethernet ports
1
Total serial ports
2
RS485
2
RS232
—
CAN ports
—
KNX TP ports
—
Two-wire MBus ports
—
DI channels
—
DO channels
—
AI channels
—
AO channels
—
Touchscreen
Included
Port and model notes
Filters use only specifications explicitly shared by every hardware edition listed here. Check the matching document below for processor, power and other edition-specific differences.