SUNFULL / PRODUCT GUIDE

Compare models in a series

Explore model variants side by side. Compare acquisition scope, forwarding protocols and physical ports, then open a model for its full specifications and documents.

Select by requirements

68 matching models · 219 in the catalog

Showing 1–4 of 68
How to choose within a series

Choose for your project

Match device-side protocols and the host system first, then check ports, wireless connections and capacity. Candidates below use confirmed model specifications.

You need multiple serial and Ethernet protocols

Check models confirmed to cover all acquisition protocols for serial and Ethernet connections. Check protocol scope and physical port counts separately. Confirm dedicated CAN, KNX TP and 2-wire MBus connections for the specific model.

Confirmed candidates36 models
  • C2M2004-ARM

    All serial and Ethernet acquisition protocols

    Forwarding: Modbus RTU / Modbus TCP / OPC UA

  • EC1024-ARM

    All serial and Ethernet acquisition protocols

    Forwarding: EtherCAT / OPC UA

  • EIP1001-ARM

    All serial and Ethernet acquisition protocols

    Forwarding: EtherNet/IP / OPC UA

Show 5 more models
  • EIP1002-ARM

    All serial and Ethernet acquisition protocols

    Forwarding: EtherNet/IP / OPC UA

  • EIP2004-A9

    All serial and Ethernet acquisition protocols

    Forwarding: EtherNet/IP / OPC UA

  • EIP2004-ARM

    All serial and Ethernet acquisition protocols

    Forwarding: EtherNet/IP / OPC UA

  • HMI1001-ARM-4G

    All serial and Ethernet acquisition protocols

    Forwarding: BACnet / Modbus / MQTT / Database / OPC UA

  • HMI1002-ARM-4G

    All serial and Ethernet acquisition protocols

    Forwarding: BACnet / Modbus / MQTT / Database / OPC UA

8 of 36 models listed; continue filtering and checking full specifications.

View full group specifications

The site uses OPC, Modbus and BACnet families

Start by checking these three families for HMI1002-Lite and the listed variants with the same scope. For other acquisition protocols, check models with the corresponding coverage.

Confirmed candidates1 models
  • HMI1002-LITE-4G

    Acquisition families: OPC / Modbus / BACnet

    Forwarding: BACnet / Modbus / MQTT / Database / OPC UA

View full group specifications

Device-side acquisition only needs Modbus RTU

The listed HMI1002-Lite-E variants have confirmed Modbus RTU acquisition. Lite-E scope differs by series; this rule does not apply to every Lite-E model.

Confirmed candidates1 models
Continue filtering by protocol

The device protocol is fixed

Check each model’s listed acquisition protocols and the required host-system protocol. A model suffix alone does not establish equivalent acquisition capability.

Confirmed candidates19 models
  • HMI1001-Lite-4G

    Listed acquisition protocols: BACnet / Modbus

    Forwarding: BACnet / Modbus / MQTT / Database / OPC UA

  • HMI1001-Lite-E(4G)

    Listed acquisition protocols: Modbus RTU / Modbus TCP

    Forwarding: BACnet / Modbus / MQTT / OPC UA

  • MOD1001-Lite

    Listed acquisition protocols: Modbus / BACnet

    Forwarding: Modbus RTU / Modbus TCP / OPC UA

Show 5 more models
  • MOD1001-Lite-E

    Listed acquisition protocols: Modbus RTU

    Forwarding: Modbus TCP / OPC UA

  • MOD1002-Lite

    Listed acquisition protocols: Modbus / BACnet

    Forwarding: Modbus RTU / Modbus TCP / OPC UA

  • MOD1002-Lite-E

    Listed acquisition protocols: Modbus RTU

    Forwarding: Modbus RTU / Modbus TCP / OPC UA

  • MOD1004-Lite

    Listed acquisition protocols: Modbus / BACnet

    Forwarding: Modbus RTU / Modbus TCP / OPC UA

  • MOD1004-Lite-E

    Listed acquisition protocols: Modbus RTU

    Forwarding: Modbus RTU / Modbus TCP / OPC UA

8 of 19 models listed; continue filtering and checking full specifications.

View full group specifications

Acquisition scope needs confirmation

These models have no listed acquisition scope suitable for this decision. Check their model notes and provide device make, model and protocol documentation.

Models to verify9 models
Show 5 more models

8 of 9 models listed; continue filtering and checking full specifications.

View full group specifications

This guidance narrows the candidates. Confirm communication roles, read/write direction, the point list, wiring and model-specific resources before final selection.

“Unconfirmed” means documentation does not establish a value; it does not mean zero or unsupported.

Compare models in a series
ModelDevice acquisition → System forwarding
SUNFULL
C2M2004-ARM
SUNFULL
EC1024-ARM
EIP1001-ARM
EIP1002-ARM
01Acquisition scopeDevice side
All acquisition protocols for serial and Ethernet connections
All acquisition protocols for serial and Ethernet connections
All acquisition protocols for serial and Ethernet connections
All acquisition protocols for serial and Ethernet connections
02Forwarding protocolsSystem side
Modbus RTUModbus TCPOPC UA
EtherCATOPC UA
EtherNet/IPOPC UA
EtherNet/IPOPC UA
Point capacity10241024256512
Device capacity41283264
Ethernet ports2311
Total serial ports4412
RS4854412
RS232————
CAN ports————
KNX TP ports————
Two-wire MBus ports————
DI channels————
DO channels————
AI channels————
AO channels————
Touchscreen————
Model documentsSpecifications & downloads
Port and model notes

The hardware platform matches PFN1024-ARM: 3 Ethernet ports and 4 isolated RS485 channels. Check the EC1024-ARM wiring instructions for the role of each Ethernet port.

Specifications & downloads
Port and model notes

Supported acquisition protocols: more than 500 protocols.

Specifications & downloads
Port and model notes

Supported acquisition protocols: more than 500 protocols.

Specifications & downloads
SUNFULL
C2M2004-ARM

01Acquisition scopeDevice side

All acquisition protocols for serial and Ethernet connections

02Forwarding protocolsSystem side

Modbus RTUModbus TCPOPC UA
Point capacity
1024
Device capacity
4
Ethernet ports
2
Total serial ports
4
RS485
4
RS232
—
CAN ports
—
KNX TP ports
—
Two-wire MBus ports
—
DI channels
—
DO channels
—
AI channels
—
AO channels
—
Touchscreen
—
Specifications & downloads
SUNFULL
EC1024-ARM

01Acquisition scopeDevice side

All acquisition protocols for serial and Ethernet connections

02Forwarding protocolsSystem side

EtherCATOPC UA
Point capacity
1024
Device capacity
128
Ethernet ports
3
Total serial ports
4
RS485
4
RS232
—
CAN ports
—
KNX TP ports
—
Two-wire MBus ports
—
DI channels
—
DO channels
—
AI channels
—
AO channels
—
Touchscreen
—
Port and model notes

The hardware platform matches PFN1024-ARM: 3 Ethernet ports and 4 isolated RS485 channels. Check the EC1024-ARM wiring instructions for the role of each Ethernet port.

Specifications & downloads
EIP1001-ARM

01Acquisition scopeDevice side

All acquisition protocols for serial and Ethernet connections

02Forwarding protocolsSystem side

EtherNet/IPOPC UA
Point capacity
256
Device capacity
32
Ethernet ports
1
Total serial ports
1
RS485
1
RS232
—
CAN ports
—
KNX TP ports
—
Two-wire MBus ports
—
DI channels
—
DO channels
—
AI channels
—
AO channels
—
Touchscreen
—
Port and model notes

Supported acquisition protocols: more than 500 protocols.

Specifications & downloads
EIP1002-ARM

01Acquisition scopeDevice side

All acquisition protocols for serial and Ethernet connections

02Forwarding protocolsSystem side

EtherNet/IPOPC UA
Point capacity
512
Device capacity
64
Ethernet ports
1
Total serial ports
2
RS485
2
RS232
—
CAN ports
—
KNX TP ports
—
Two-wire MBus ports
—
DI channels
—
DO channels
—
AI channels
—
AO channels
—
Touchscreen
—
Port and model notes

Supported acquisition protocols: more than 500 protocols.

Specifications & downloads

“—” means the documentation does not establish a value; 0 is a confirmed zero. Check model documentation for shared ports, options and protocol roles.