SUNFULL / PRODUCT GUIDE

Compare models in a series

Explore model variants side by side. Compare acquisition scope, forwarding protocols and physical ports, then open a model for its full specifications and documents.

Select by requirements

38 matching models · 219 in the catalog

Showing 1–4 of 38
How to choose within a series

Choose for your project

Match device-side protocols and the host system first, then check ports, wireless connections and capacity. Candidates below use confirmed model specifications.

You need multiple serial and Ethernet protocols

Check models confirmed to cover all acquisition protocols for serial and Ethernet connections. Check protocol scope and physical port counts separately. Confirm dedicated CAN, KNX TP and 2-wire MBus connections for the specific model.

Confirmed candidates17 models
  • C2M2004-ARM

    All serial and Ethernet acquisition protocols

    Forwarding: Modbus RTU / Modbus TCP / OPC UA

  • MOD1001-ARM

    All serial and Ethernet acquisition protocols

    Forwarding: Modbus RTU / Modbus TCP / OPC UA

  • MOD1002-ARM

    All serial and Ethernet acquisition protocols

    Forwarding: Modbus RTU / Modbus TCP / OPC UA

Show 5 more models
  • MOD1002-ARM(NXP)

    All serial and Ethernet acquisition protocols

    Forwarding: Modbus RTU / Modbus TCP / OPC UA

  • MOD1004-ARM

    All serial and Ethernet acquisition protocols

    Forwarding: Modbus RTU / Modbus TCP / OPC UA

  • MOD1006-ARM

    All serial and Ethernet acquisition protocols

    Forwarding: Modbus RTU / Modbus TCP / OPC UA

  • MOD1008-ARM

    All serial and Ethernet acquisition protocols

    Forwarding: Modbus RTU / Modbus TCP / OPC UA

  • MOD1302-ARM

    All serial and Ethernet acquisition protocols

    Forwarding: Modbus RTU / Modbus TCP / OPC UA

8 of 17 models listed; continue filtering and checking full specifications.

View full group specifications

The device protocol is fixed

Check each model’s listed acquisition protocols and the required host-system protocol. A model suffix alone does not establish equivalent acquisition capability.

Confirmed candidates17 models
  • MOD1001-Lite

    Listed acquisition protocols: Modbus / BACnet

    Forwarding: Modbus RTU / Modbus TCP / OPC UA

  • MOD1001-Lite-E

    Listed acquisition protocols: Modbus RTU

    Forwarding: Modbus TCP / OPC UA

  • MOD1002-Lite

    Listed acquisition protocols: Modbus / BACnet

    Forwarding: Modbus RTU / Modbus TCP / OPC UA

Show 5 more models
  • MOD1002-Lite-E

    Listed acquisition protocols: Modbus RTU

    Forwarding: Modbus RTU / Modbus TCP / OPC UA

  • MOD1004-Lite

    Listed acquisition protocols: Modbus / BACnet

    Forwarding: Modbus RTU / Modbus TCP / OPC UA

  • MOD1004-Lite-E

    Listed acquisition protocols: Modbus RTU

    Forwarding: Modbus RTU / Modbus TCP / OPC UA

  • MOD1006-Lite

    Listed acquisition protocols: Modbus / BACnet

    Forwarding: Modbus RTU / Modbus TCP / OPC UA

  • MOD1006-Lite-E

    Listed acquisition protocols: Modbus RTU

    Forwarding: Modbus RTU / Modbus TCP / OPC UA

8 of 17 models listed; continue filtering and checking full specifications.

View full group specifications

Acquisition scope needs confirmation

These models have no listed acquisition scope suitable for this decision. Check their model notes and provide device make, model and protocol documentation.

Models to verify4 models
Show 1 more models
View full group specifications

This guidance narrows the candidates. Confirm communication roles, read/write direction, the point list, wiring and model-specific resources before final selection.

“Unconfirmed” means documentation does not establish a value; it does not mean zero or unsupported.

Compare models in a series
ModelDevice acquisition → System forwarding
SUNFULL
C2M2004-ARM
MOD1001-ARM
MOD1001-Lite
MOD1001-Lite-E
01Acquisition scopeDevice side
All acquisition protocols for serial and Ethernet connections
All acquisition protocols for serial and Ethernet connections
Listed acquisition protocols
SimulatorModbusBACnet
Listed acquisition protocols
Modbus RTUSimulator
02Forwarding protocolsSystem side
Modbus RTUModbus TCPOPC UA
Modbus RTUModbus TCPOPC UA
Modbus RTUModbus TCPOPC UA
Modbus TCPOPC UA
Point capacity1024256256256
Device capacity4323232
Ethernet ports2111
Total serial ports4111
RS4854111
RS232————
CAN ports————
KNX TP ports————
Two-wire MBus ports————
DI channels————
DO channels————
AI channels————
AO channels————
Touchscreen————
Model documentsSpecifications & downloads
Port and model notes

Supported acquisition protocols: more than 500 protocols.

Specifications & downloads
Specifications & downloadsSpecifications & downloads
SUNFULL
C2M2004-ARM

01Acquisition scopeDevice side

All acquisition protocols for serial and Ethernet connections

02Forwarding protocolsSystem side

Modbus RTUModbus TCPOPC UA
Point capacity
1024
Device capacity
4
Ethernet ports
2
Total serial ports
4
RS485
4
RS232
—
CAN ports
—
KNX TP ports
—
Two-wire MBus ports
—
DI channels
—
DO channels
—
AI channels
—
AO channels
—
Touchscreen
—
Specifications & downloads
MOD1001-ARM

01Acquisition scopeDevice side

All acquisition protocols for serial and Ethernet connections

02Forwarding protocolsSystem side

Modbus RTUModbus TCPOPC UA
Point capacity
256
Device capacity
32
Ethernet ports
1
Total serial ports
1
RS485
1
RS232
—
CAN ports
—
KNX TP ports
—
Two-wire MBus ports
—
DI channels
—
DO channels
—
AI channels
—
AO channels
—
Touchscreen
—
Port and model notes

Supported acquisition protocols: more than 500 protocols.

Specifications & downloads
MOD1001-Lite

01Acquisition scopeDevice side

Listed acquisition protocols
SimulatorModbusBACnet

02Forwarding protocolsSystem side

Modbus RTUModbus TCPOPC UA
Point capacity
256
Device capacity
32
Ethernet ports
1
Total serial ports
1
RS485
1
RS232
—
CAN ports
—
KNX TP ports
—
Two-wire MBus ports
—
DI channels
—
DO channels
—
AI channels
—
AO channels
—
Touchscreen
—
Specifications & downloads
MOD1001-Lite-E

01Acquisition scopeDevice side

Listed acquisition protocols
Modbus RTUSimulator

02Forwarding protocolsSystem side

Modbus TCPOPC UA
Point capacity
256
Device capacity
32
Ethernet ports
1
Total serial ports
1
RS485
1
RS232
—
CAN ports
—
KNX TP ports
—
Two-wire MBus ports
—
DI channels
—
DO channels
—
AI channels
—
AO channels
—
Touchscreen
—
Specifications & downloads

“—” means the documentation does not establish a value; 0 is a confirmed zero. Check model documentation for shared ports, options and protocol roles.