IOM8600
Expands PLC or DDC field I/O over Modbus RTU with 8 DI, 6 DO, connecting digital signals to the control system.
Find the right connection between field interfaces and system protocols.
Filters use documented product information. Unspecified capabilities are excluded. Confirm protocol roles, device models, point counts and site conditions before ordering.
Select a condition to remove it. Multiple protocols still require an AND match.

Expands PLC or DDC field I/O over Modbus RTU with 8 DI, 6 DO, connecting digital signals to the control system.

Connects meter MBus wiring to RS485 through five MBus terminal groups, allowing a host or serial device to access field meters.

Supports field-data acquisition and MQTT integration, with acquisition and forwarding configured from the device point list to connect serial or network devices to supervisory platforms. Provides 2 Ethernet ports, 4 serial ports, 1024-point capacity. Acquisition protocols: Modbus RTU, Modbus TCP; a Simulator driver is also included.

Converts field-device data to IEC104 or IEC61850 for integration with supervisory systems using those protocols. Provides 2 Ethernet ports, 4 serial ports, 1024-point capacity. Acquisition covers more than 500 protocols; check the driver against each connected device.

Supports field-data acquisition and MQTT integration, with acquisition and forwarding configured from the device point list to connect serial or network devices to supervisory platforms. Provides 1 Ethernet port, 1 serial port, 256-point capacity. Acquisition protocols: Modbus RTU, Modbus TCP; a Simulator driver is also included.

Collects field-device data and exposes an SNMP agent interface for equipment-status access from data-center or network-management systems. Provides 1 Ethernet port, 1 serial port, 256-point capacity. Acquisition covers more than 500 protocols; check the driver against each connected device.

Integrates field-device data with Siemens S7 systems using the documented protocol directions and point capacity of this model. Provides 2 Ethernet ports, 4 serial ports, 2048-point capacity. Acquisition covers more than 500 protocols; check the driver against each connected device.

Integrates field-device data with Siemens S7 systems using the documented protocol directions and point capacity of this model. Provides 1 Ethernet port, 1 serial port, 256-point capacity. Acquisition covers more than 500 protocols; check the driver against each connected device.

Integrates water, heat and other meter data into Siemens S7 systems. Configure the MBus wiring, acquisition driver and supply for the selected edition. Select the matching hardware edition below.

Exposes field-device data through Modbus interfaces for PLCs, HMI software or other Modbus clients, bringing different devices into a common data interface. Provides 1 Ethernet port, 2 serial ports, 512-point capacity. Acquisition protocols: Modbus RTU; a Simulator driver is also included.

Organizes field-device data into browser-based HMI screens for building or industrial monitoring and provides interfaces for other supervisory systems. Provides 1 Ethernet port, 2 serial ports, 512-point capacity. Acquisition covers more than 500 protocols; check the driver against each connected device. This model supports 4G.

Transparently connects Modbus RTU serial buses to a Modbus TCP network without per-point mapping; clients distinguish buses and devices by port and station address. Provides 1 Ethernet port, 1 serial port. Acquisition covers all serial and Ethernet protocols in the reviewed list. Existing explicit support for Modbus RTU is retained.