IOM0080T
Adds 8 resistance-temperature input channels to a PLC or DDC through Modbus RTU, covering the listed Pt1000, Ni1000, NTC, Pt100, Cu100 and Cu50 sensor types.
Find the right connection between field interfaces and system protocols.
Filters use documented product information. Unspecified capabilities are excluded. Confirm protocol roles, device models, point counts and site conditions before ordering.
Select a condition to remove it. Multiple protocols still require an AND match.

Adds 8 resistance-temperature input channels to a PLC or DDC through Modbus RTU, covering the listed Pt1000, Ni1000, NTC, Pt100, Cu100 and Cu50 sensor types.

Integrates water, heat and other meter data into BACnet systems. Configure the MBus wiring, acquisition driver and supply for the selected edition. Provides 1 Ethernet port, 1 serial port, 1 two-wire MBus port. Select the matching hardware edition below.

Exposes field-device data through Modbus interfaces for PLCs, HMI software or other Modbus clients, bringing different devices into a common data interface. Provides 1 Ethernet port, 1 serial port, 256-point capacity. Acquisition covers more than 500 protocols; check the driver against each connected device.

Splits one RS485 connection into two RS485 branches with optoelectronic isolation and signal regeneration for half-duplex serial networks requiring isolated branches or extension.

7-inch web HMI touchscreen for field-data collection and local touch operation, with browser access to the monitoring project from a phone, tablet or PC. Provides 1 Ethernet port, 2048-point capacity. WiFi is optional; confirm the option when ordering.

Organizes field-device data into browser-based HMI screens for building or industrial monitoring and provides interfaces for other supervisory systems. Provides 1 Ethernet port, 2 serial ports, 512-point capacity. Acquisition is limited to the OPC, Modbus and BACnet protocol families.

Connects field-device communications to OPC DA, OPC XML-DA and OPC UA supervisory systems and provides web access for integration with existing HMI software. Uses a software license for one PC.

Collects field-device data and exposes an SNMP agent interface for equipment-status access from data-center or network-management systems. Provides 2 Ethernet ports, 4 serial ports, 1024-point capacity. Acquisition covers more than 500 protocols; check the driver against each connected device.

Combines local digital or analog terminals with Modbus and BACnet device communications for gateway-style DDC applications requiring both field I/O and supervisory integration. Provides 1 Ethernet port, 1 serial port, 2 DI, 2 DO, 2 AI, 256-point capacity. Acquisition protocols: Modbus, BACnet; a Simulator driver is also included. This model supports 4G.

Converts field-controller and meter data into BACnet interfaces for point-list-based integration with building management systems. Provides 2 Ethernet ports, 4 serial ports, 2048-point capacity. Acquisition covers more than 500 protocols; check the driver against each connected device.
Integrates Carrier CCN air-conditioning units into a Modbus supervisory system, with one unit per COM port and up to four units in total. Provides 2 Ethernet ports, 4 serial ports, 1024-point capacity. Acquisition covers all serial and Ethernet protocols in the reviewed list. Existing explicit support for CCN is retained.

Converts field-device data to Profinet and OPC UA for integration with Profinet control systems and supervisory platforms, using X2Profinet to configure points and device communications. Provides 3 Ethernet ports, 4 serial ports, 1024-point capacity. Acquisition covers more than 500 protocols; check the driver against each connected device.