SUNFULL / PRODUCTS

Products

Find the right connection between field interfaces and system protocols.

PRODUCT FINDER

Find your connection

Select multiple protocols or enter your own. Results must meet every selected requirement.

01 / Device / acquisition protocol
1 selected
A–Z order · Search keeps list numbers

Names are from the supplied acquisition protocol list.

Showing all 579 protocols

Modbus RTU
02 / System / forwarding protocol
Select protocols · multiple
A–Z order · Search keeps list numbers

Choose forwarding protocols or database integration. Support depends on the model documentation.

Showing all 20 protocols

Select physical interfaces separately from acquisition protocols. CAN, KNX TP and two-wire MBus ports have independent counts; protocol support does not establish a physical port. USB Type-C includes power connectors; check each model's documentation for data communication support.

DDC I/O and touchscreenRefine by product type

When a touchscreen is required, results must have a built-in touchscreen and meet all I/O counts. Otherwise, positive I/O counts select DDC controllers. Counts are minimum requirements. HMI configuration support does not imply a built-in screen.

Power and wireless connectivityAdditional requirements

Checked requirements match only confirmed capabilities. Review product notes for optional modules, shared ports and power conditions.

Filters use documented product information. Unspecified capabilities are excluded. Confirm protocol roles, device models, point counts and site conditions before ordering.

48 results

Current selection conditions

Select a condition to remove it. Multiple protocols still require an AND match.

HMI2004-ARM-4G
HMI / web visualization gateways

HMI2004-ARM-4G

Organizes field-device data into browser-based HMI screens for building or industrial monitoring and provides interfaces for other supervisory systems. Provides 2 Ethernet ports, 4 serial ports, 1024-point capacity. Acquisition covers more than 500 protocols; check the driver against each connected device. This model supports 4G.

RS485 ports4 portsRS232 ports—Ethernet ports2 portsSerial ports4 ports
HMI configurationAll acquisition protocols for serial and Ethernet connectionsBACnetModbusMQTTDatabase
Why this matches
  • Acquisition protocolsModbus RTU

Confirm communication roles, capacity and installation conditions.

MOD2004-ARM
Modbus gateways

MOD2004-ARM

Exposes field-device data through Modbus interfaces for PLCs, HMI software or other Modbus clients, bringing different devices into a common data interface. Provides 2 Ethernet ports, 4 serial ports, 1024-point capacity. Acquisition covers more than 500 protocols; check the driver against each connected device.

RS485 ports4 portsRS232 ports—Ethernet ports2 portsSerial ports4 ports
All acquisition protocols for serial and Ethernet connectionsModbus RTUModbus TCPOPC UA
Why this matches
  • Acquisition protocolsModbus RTU

Confirm communication roles, capacity and installation conditions.

MOD2004-ARM-E
Modbus gateways

MOD2004-ARM-E

Exposes field-device data through Modbus interfaces for PLCs, HMI software or other Modbus clients, bringing different devices into a common data interface. Provides 2 Ethernet ports, 4 serial ports, 1024-point capacity. Acquisition covers more than 500 protocols; check the driver against each connected device.

RS485 ports4 portsRS232 ports—Ethernet ports2 portsSerial ports4 ports
All acquisition protocols for serial and Ethernet connectionsModbus RTUModbus TCPOPC UA
Why this matches
  • Acquisition protocolsModbus RTU

Confirm communication roles, capacity and installation conditions.

PFN2004-ARM
PROFINET / S7 gateways

PFN2004-ARM

Integrates field-device data with Siemens S7 systems using the documented protocol directions and point capacity of this model. Provides 2 Ethernet ports, 4 serial ports, 1024-point capacity. Acquisition covers more than 500 protocols; check the driver against each connected device.

RS485 ports4 portsRS232 ports—Ethernet ports2 portsSerial ports4 ports
All acquisition protocols for serial and Ethernet connectionsS7OPC UA
Why this matches
  • Acquisition protocolsModbus RTU

Confirm communication roles, capacity and installation conditions.

EIP1002-ARM
EtherNet/IP gateways

EIP1002-ARM

Integrates field-device data into EtherNet/IP systems for connection to PLCs or supervisory platforms using that protocol. Provides 1 Ethernet port, 2 serial ports, 512-point capacity. Acquisition covers more than 500 protocols; check the driver against each connected device.

RS485 ports2 portsRS232 ports—Ethernet ports1 portsSerial ports2 ports
All acquisition protocols for serial and Ethernet connectionsEtherNet/IPOPC UA
Why this matches
  • Acquisition protocolsModbus RTU

Confirm communication roles, capacity and installation conditions.

MOD1002-ARM
Modbus gateways

MOD1002-ARM

Exposes field-device data through Modbus interfaces for PLCs, HMI software or other Modbus clients, bringing different devices into a common data interface. Provides 1 Ethernet port, 2 serial ports, 512-point capacity. Acquisition covers more than 500 protocols; check the driver against each connected device.

RS485 ports2 portsRS232 ports—Ethernet ports1 portsSerial ports2 ports
All acquisition protocols for serial and Ethernet connectionsModbus RTUModbus TCPOPC UA
Why this matches
  • Acquisition protocolsModbus RTU

Confirm communication roles, capacity and installation conditions.

RT5001-WiFi
Transparent transmission & remote network routers

RT5001-WiFi

Combines transparent transmission, VPN networking and device-data gateway functions for remote maintenance of PLCs, touchscreens and building or industrial equipment. It provides 1 WAN port, 4 LAN ports, 1 RS485 port and WiFi 5 for planning network access and protocol integration together.

RS485 ports1 portsRS232 ports—Ethernet ports5 portsSerial ports1 ports
HMI configurationBACnet/IPModbus TCPMQTT
Why this matches
  • Acquisition protocolsModbus RTU

Confirm communication roles, capacity and installation conditions.

MOD1006-ARM
Modbus gateways

MOD1006-ARM

Exposes field-device data through Modbus interfaces for PLCs, HMI software or other Modbus clients, bringing different devices into a common data interface. Provides 1 Ethernet port, 6 serial ports, 1536-point capacity. Acquisition covers more than 500 protocols; check the driver against each connected device.

RS485 ports6 portsRS232 ports—Ethernet ports1 portsSerial ports6 ports
All acquisition protocols for serial and Ethernet connectionsModbus RTUModbus TCPOPC UA
Why this matches
  • Acquisition protocolsModbus RTU

Confirm communication roles, capacity and installation conditions.

MB1002-ARM-E
Modbus routers

MB1002-ARM-E

Transparently connects Modbus RTU serial buses to a Modbus TCP network without per-point mapping; clients distinguish buses and devices by port and station address. Provides 1 Ethernet port, 2 serial ports. Acquisition covers all serial and Ethernet protocols in the reviewed list. Existing explicit support for Modbus RTU is retained.

RS485 ports2 portsRS232 ports—Ethernet ports1 portsSerial ports2 ports
All acquisition protocols for serial and Ethernet connectionsModbus TCP
Why this matches
  • Acquisition protocolsModbus RTU

Confirm communication roles, capacity and installation conditions.

MOD1002-ARM(NXP)
Modbus gateways

MOD1002-ARM(NXP)

Exposes field-device data through Modbus interfaces for PLCs, HMI software or other Modbus clients, bringing different devices into a common data interface. Provides 1 Ethernet port, 2 serial ports, 512-point capacity. Acquisition covers more than 500 protocols; check the driver against each connected device. This model supports Type-C power. This page covers the NXP edition.

RS485 ports2 portsRS232 ports—Ethernet ports1 portsSerial ports2 ports
All acquisition protocols for serial and Ethernet connectionsModbus RTUModbus TCPOPC UA
Why this matches
  • Acquisition protocolsModbus RTU

Confirm communication roles, capacity and installation conditions.

EIP2004-A9
EtherNet/IP gateways

EIP2004-A9

Integrates field-device data into EtherNet/IP systems for connection to PLCs or supervisory platforms using that protocol. Provides 2 Ethernet ports, 4 serial ports, 2048-point capacity. Acquisition covers more than 500 protocols; check the driver against each connected device.

RS485 ports4 portsRS232 ports—Ethernet ports2 portsSerial ports4 ports
All acquisition protocols for serial and Ethernet connectionsEtherNet/IPOPC UA
Why this matches
  • Acquisition protocolsModbus RTU

Confirm communication roles, capacity and installation conditions.

MOD1004-ARM
Modbus gateways

MOD1004-ARM

Exposes field-device data through Modbus interfaces for PLCs, HMI software or other Modbus clients, bringing different devices into a common data interface. Provides 1 Ethernet port, 4 serial ports, 1024-point capacity. Acquisition covers more than 500 protocols; check the driver against each connected device.

RS485 ports4 portsRS232 ports—Ethernet ports1 portsSerial ports4 ports
All acquisition protocols for serial and Ethernet connectionsModbus RTUModbus TCPOPC UA
Why this matches
  • Acquisition protocolsModbus RTU

Confirm communication roles, capacity and installation conditions.