Showing all 579 protocols

02 / System / forwarding protocol
1 selected
A–Z order · Search keeps list numbers

Names are from documented product forwarding protocols.

Showing all 19 protocols

MQTT

Select physical interfaces separately from acquisition protocols. CAN, KNX TP and two-wire MBus ports have independent counts; protocol support does not establish a physical port.

DDC I/O and touchscreenRefine by product type

When a touchscreen is required, results must have a built-in touchscreen and meet all I/O counts. Otherwise, positive I/O counts select DDC controllers. Counts are minimum requirements. HMI configuration support does not imply a built-in screen.

Power and wireless connectivityAdditional requirements

Checked requirements match only confirmed capabilities. Review product notes for optional modules, shared ports and power conditions.

Filters use documented product information. Unspecified capabilities are excluded. Confirm protocol roles, device models, point counts and site conditions before ordering.

84 results

Current selection conditions

Select a condition to remove it. Multiple protocols still require an AND match.

I43-1031
Touch Panel - I Series 86box

I43-1031

43-inch web HMI touchscreen for field-data collection and local touch operation, with browser access to the monitoring project from a phone, tablet or PC. Provides 1 Ethernet port, 2048-point capacity. WiFi is optional; confirm the option when ordering.

RS485 ports3 portsRS232 ports1 portsEthernet ports1 portsSerial ports0
HMI configurationBACnetModbusMQTT
Why this matches
  • Forwarding protocolsMQTT

Confirm communication roles, capacity and installation conditions.

HMI1002-Lite-E(4G)
HMI Gateway

HMI1002-Lite-E(4G)

Supports field-data acquisition and MQTT integration, with acquisition and forwarding configured from the device point list to connect serial or network devices to supervisory platforms. Provides 1 Ethernet port, 2 serial ports, 512-point capacity. Acquisition protocols: Modbus RTU, Modbus TCP; a Simulator driver is also included. This model supports 4G.

RS485 ports2 portsRS232 ports0Ethernet ports1 portsSerial ports2 ports
Listed protocols · Modbus RTU / Modbus TCP / SimulatorBACnetModbusMQTT
Why this matches
  • Forwarding protocolsMQTT

Confirm communication roles, capacity and installation conditions.

HMI2000-EMS
EMS

HMI2000-EMS

Collects, bills, stores and classifies water, electricity, gas and heating/cooling energy data, with time-of-use electricity records and charts for reviewing building or equipment consumption. Provides 2 Ethernet ports, 2048-point capacity. Acquisition covers more than 500 protocols; check the driver against each connected device.

RS485 ports0RS232 ports0Ethernet ports2 portsSerial ports0
BACnet/IPModbus TCPMQTT
Why this matches
  • Forwarding protocolsMQTT

Confirm communication roles, capacity and installation conditions.

HMI1002-KNX-TP
KNX Gateway

HMI1002-KNX-TP

Reads and controls lighting and other KNX TP bus devices, with built-in web HMI functions and data interfaces for BACnet, Modbus, OPC UA and MQTT systems. Provides 1 Ethernet port, 1 serial port, 1 KNX TP port, 512-point capacity. Acquisition covers more than 500 protocols; check the driver against each connected device. This model supports Type-C power.

RS485 ports1 portsRS232 ports0Ethernet ports1 portsSerial ports1 portsKNX TP ports1 ports
HMI configurationModbusBACnetMQTT
Why this matches
  • Forwarding protocolsMQTT

Confirm communication roles, capacity and installation conditions.

HMI2002-ARM-E
HMI Gateway

HMI2002-ARM-E

Organizes field-device data into browser-based HMI screens for building or industrial monitoring and provides interfaces for other supervisory systems. Provides 2 Ethernet ports, 2 serial ports, 512-point capacity. Acquisition covers more than 500 protocols; check the driver against each connected device.

RS485 ports2 portsRS232 ports0Ethernet ports2 portsSerial ports2 ports
HMI configurationBACnetModbusMQTT
Why this matches
  • Forwarding protocolsMQTT

Confirm communication roles, capacity and installation conditions.

A7-1341
Customized products

A7-1341

7-inch web HMI touchscreen for field-data collection and local touch operation, with browser access to the monitoring project from a phone, tablet or PC. Provides 1 Ethernet port, 2 serial ports, 2048-point capacity. WiFi is optional; confirm the option when ordering. This is a custom edition; confirm the delivery configuration against its own document.

RS485 ports2 portsRS232 ports0Ethernet ports1 portsSerial ports2 ports
HMI configurationBACnetModbusMQTT
Why this matches
  • Forwarding protocolsMQTT

Confirm communication roles, capacity and installation conditions.

HMI2004-ARM-WiFi
HMI Gateway

HMI2004-ARM-WiFi

Organizes field-device data into browser-based HMI screens for building or industrial monitoring and provides interfaces for other supervisory systems. Provides 2 Ethernet ports, 4 serial ports, 1024-point capacity. Acquisition covers more than 500 protocols; check the driver against each connected device. This model supports WiFi.

RS485 ports4 portsRS232 ports0Ethernet ports2 portsSerial ports4 ports
HMI configurationBACnetModbusMQTT
Why this matches
  • Forwarding protocolsMQTT

Confirm communication roles, capacity and installation conditions.

HMI1002-Lite(NXP)
HMI Gateway

HMI1002-Lite(NXP)

Organizes field-device data into browser-based HMI screens for building or industrial monitoring and provides interfaces for other supervisory systems. Provides 1 Ethernet port, 2 serial ports, 512-point capacity. Acquisition protocols: Modbus, BACnet; a Simulator driver is also included. This model supports Type-C power. This page covers the NXP edition.

RS485 ports2 portsRS232 ports0Ethernet ports1 portsSerial ports2 ports
HMI configurationBACnetModbusMQTT
Why this matches
  • Forwarding protocolsMQTT

Confirm communication roles, capacity and installation conditions.

HMI1002-Lite-E
HMI Gateway

HMI1002-Lite-E

Collect Modbus RTU/TCP device data using 1 Ethernet port, 2 RS485 ports and a 512-point capacity. Connect field devices to BACnet or Modbus supervisory systems and use the gateway’s MQTT service for building or industrial monitoring applications.

RS485 ports2 portsRS232 ports0Ethernet ports1 portsSerial ports2 ports
Listed protocols · Modbus RTU / Modbus TCP / SimulatorBACnetModbusMQTT
Why this matches
  • Forwarding protocolsMQTT

Confirm communication roles, capacity and installation conditions.

HMI2001-Lite
HMI Gateway

HMI2001-Lite

Organizes field-device data into browser-based HMI screens for building or industrial monitoring and provides interfaces for other supervisory systems. Provides 2 Ethernet ports, 1 serial port, 1024-point capacity. Acquisition protocols: Modbus, BACnet, OPC XML-DA; a Simulator driver is also included.

RS485 ports1 portsRS232 ports0Ethernet ports2 portsSerial ports1 ports
HMI configurationBACnetModbusMQTT
Why this matches
  • Forwarding protocolsMQTT

Confirm communication roles, capacity and installation conditions.

HMI2004-EMS(RK3568)
EMS

HMI2004-EMS(RK3568)

Collects, bills, stores and classifies water, electricity, gas and heating/cooling energy data, with time-of-use electricity records and charts for reviewing building or equipment consumption. Provides 2 Ethernet ports, 4 serial ports, 2048-point capacity. Acquisition covers more than 500 protocols; check the driver against each connected device. This page covers the RK3568 hardware edition.

RS485 ports4 portsRS232 ports0Ethernet ports2 portsSerial ports4 ports
BACnetModbusMQTT
Why this matches
  • Forwarding protocolsMQTT

Confirm communication roles, capacity and installation conditions.