IOM0080
Expands PLC or DDC field I/O over Modbus RTU with 8 AI, connecting analog signals to the control system.
Find the right connection between field interfaces and system protocols.
Filters use documented product information. Unspecified capabilities are excluded. Confirm protocol roles, device models, point counts and site conditions before ordering.

Expands PLC or DDC field I/O over Modbus RTU with 8 AI, connecting analog signals to the control system.
web HMI touchscreen for field-data collection and local touch operation, with browser access to the monitoring project from a phone, tablet or PC. Provides 1 Ethernet port, 2048-point capacity. WiFi is optional; confirm the option when ordering.

Organizes field-device data into browser-based HMI screens for building or industrial monitoring and provides interfaces for other supervisory systems. Provides 2 Ethernet ports, 1 serial port, 1024-point capacity. Acquisition protocols: Modbus, BACnet, OPC XML-DA; a Simulator driver is also included.

Exposes field-device data through Modbus interfaces for PLCs, HMI software or other Modbus clients, bringing different devices into a common data interface. Provides 1 Ethernet port, 2 serial ports, 512-point capacity. Acquisition covers more than 500 protocols; check the driver against each connected device. This is a custom edition; confirm the delivery configuration against its own document.

Converts field-controller and meter data into BACnet interfaces for point-list-based integration with building management systems. Provides 1 Ethernet port, 1 serial port, 256-point capacity. Acquisition covers more than 500 protocols; check the driver against each connected device.

A 8-circuit lighting-control module with Modbus RTU integration and local or emergency manual operation. Scheduling and scene control require a gateway or web touchscreen. Provides 2 serial ports.

Collects, bills, stores and classifies water, electricity, gas and heating/cooling energy data, with time-of-use electricity records and charts for reviewing building or equipment consumption. Provides 2 Ethernet ports, 4 serial ports, 2048-point capacity. Acquisition covers more than 500 protocols; check the driver against each connected device. This page covers the RK3568 hardware edition.

Converts field-controller and meter data into BACnet interfaces for point-list-based integration with building management systems. Provides 1 Ethernet port, 6 serial ports, 1536-point capacity. Acquisition protocols: Modbus RTU; a Simulator driver is also included.

Supports field-data acquisition and MQTT integration, with acquisition and forwarding configured from the device point list to connect serial or network devices to supervisory platforms. Provides 1 Ethernet port, 1 serial port, 256-point capacity. Acquisition protocols: Modbus RTU, Modbus TCP; a Simulator driver is also included. This model supports 4G.

Transparently routes between BACnet MS/TP buses and BACnet/IP networks, connecting MS/TP DDCs or valve controllers to building Ethernet. Provides 1 Ethernet port, 1 serial port. Acquisition protocols: BACnet MS/TP.

Combines field-device communications with web SCADA editing and monitoring, organizing device points, screens and the documented data sources within a project. Provides 1 Ethernet port, 4 serial ports, 1024-point capacity. Acquisition covers more than 500 protocols; check the driver against each connected device.

Converts the HBS F1/F2 connection on a Daikin VRV communication board to RS485 for host or serial-gateway access to the air-conditioning equipment.