5 matching models · 219 in the catalog
Showing 1–4 of 5 How to choose within a series How to choose within a series Match device-side protocols and the host system first, then check ports, wireless connections and capacity. Candidates below use confirmed model specifications.
Current model group BAC1002 Acquisition Physical ports 4G and wireless Capacity
You need multiple serial and Ethernet protocols Check models confirmed to cover all acquisition protocols for serial and Ethernet connections. Check protocol scope and physical port counts separately. Confirm dedicated CAN, KNX TP and 2-wire MBus connections for the specific model.
Confirmed candidates 2 models
BAC1002-ARM ↗ All serial and Ethernet acquisition protocols
Forwarding: BACnet/IP / BACnet MS/TP / OPC UA
BAC1002-ARM(NXP) ↗ All serial and Ethernet acquisition protocols
Forwarding: BACnet/IP / BACnet MS/TP / OPC UA
View full group specifications ↗ The device protocol is fixed Check each model’s listed acquisition protocols and the required host-system protocol. A model suffix alone does not establish equivalent acquisition capability.
Confirmed candidates 3 models
BAC1002-Lite ↗ Listed acquisition protocols: Modbus / BACnet
Forwarding: BACnet/IP / BACnet MS/TP / OPC UA
BAC1002-Lite-E ↗ Listed acquisition protocols: Modbus RTU
Forwarding: BACnet/IP / BACnet MS/TP / OPC UA
BAC1002-MBus ↗ Listed acquisition protocols: MBus_WaterMeter / MBus_EnergyMeter / MBus_EnergyMeter_EN / Modbus RTU / Modbus TCP / DLT645-1997/2007 / DLT645-1997 / DLT645-2007
Forwarding protocols unconfirmed
View full group specifications ↗ This guidance narrows the candidates. Confirm communication roles, read/write direction, the point list, wiring and model-specific resources before final selection.
“Unconfirmed” means documentation does not establish a value; it does not mean zero or unsupported.
Compare models in a series Model Device acquisition → System forwarding 01 Acquisition scopeDevice side All acquisition protocols for serial and Ethernet connections
All acquisition protocols for serial and Ethernet connections
Listed acquisition protocols Listed acquisition protocols 02 Forwarding protocolsSystem side BACnet/IP BACnet MS/TP OPC UA
BACnet/IP BACnet MS/TP OPC UA
BACnet/IP BACnet MS/TP OPC UA
BACnet/IP BACnet MS/TP OPC UA
Point capacity 512 512 512 512 Device capacity 64 64 64 64 Ethernet ports 1 1 1 1 Total serial ports 2 2 2 — RS485 2 2 2 — RS232 — — — — CAN ports — — — — KNX TP ports — — — — Two-wire MBus ports — — — — DI channels — — — — DO channels — — — — AI channels — — — — AO channels — — — — Touchscreen — — — — Model documents Port and model notes Supported acquisition protocols: more than 500 protocols.
Specifications & downloads ↗ Port and model notes Supported acquisition protocols: more than 500 protocols.
Specifications & downloads ↗ Specifications & downloads ↗ Port and model notes The documentation gives inconsistent values for RS485 ports, Total serial ports. These values are excluded from confirmed selection criteria.
Specifications & downloads ↗
01 Acquisition scopeDevice side All acquisition protocols for serial and Ethernet connections
02 Forwarding protocolsSystem side BACnet/IP BACnet MS/TP OPC UA
Point capacity 512
Device capacity 64
Ethernet ports 1
Total serial ports 2
RS485 2
RS232 —
CAN ports —
KNX TP ports —
Two-wire MBus ports —
DI channels —
DO channels —
AI channels —
AO channels —
Touchscreen — Port and model notes Supported acquisition protocols: more than 500 protocols.
Specifications & downloads↗ 01 Acquisition scopeDevice side All acquisition protocols for serial and Ethernet connections
02 Forwarding protocolsSystem side BACnet/IP BACnet MS/TP OPC UA
Point capacity 512
Device capacity 64
Ethernet ports 1
Total serial ports 2
RS485 2
RS232 —
CAN ports —
KNX TP ports —
Two-wire MBus ports —
DI channels —
DO channels —
AI channels —
AO channels —
Touchscreen — Port and model notes Supported acquisition protocols: more than 500 protocols.
Specifications & downloads↗ 01 Acquisition scopeDevice side Listed acquisition protocols 02 Forwarding protocolsSystem side BACnet/IP BACnet MS/TP OPC UA
Point capacity 512
Device capacity 64
Ethernet ports 1
Total serial ports 2
RS485 2
RS232 —
CAN ports —
KNX TP ports —
Two-wire MBus ports —
DI channels —
DO channels —
AI channels —
AO channels —
Touchscreen — Specifications & downloads↗ 01 Acquisition scopeDevice side Listed acquisition protocols 02 Forwarding protocolsSystem side BACnet/IP BACnet MS/TP OPC UA
Point capacity 512
Device capacity 64
Ethernet ports 1
Total serial ports —
RS485 —
RS232 —
CAN ports —
KNX TP ports —
Two-wire MBus ports —
DI channels —
DO channels —
AI channels —
AO channels —
Touchscreen — Port and model notes The documentation gives inconsistent values for RS485 ports, Total serial ports. These values are excluded from confirmed selection criteria.
Specifications & downloads↗