SUNFULL / PRODUCT GUIDE

Compare models in a series

Explore model variants side by side. Compare acquisition scope, forwarding protocols and physical ports, then open a model for its full specifications and documents.

Select by requirements

6 matching models · 219 in the catalog

Showing 1–4 of 6
How to choose within a series

How to choose within a series

Match device-side protocols and the host system first, then check ports, wireless connections and capacity. Candidates below use confirmed model specifications.

Current model groupHMI2000

You need multiple serial and Ethernet protocols

Check models confirmed to cover all acquisition protocols for serial and Ethernet connections. Check protocol scope and physical port counts separately. Confirm dedicated CAN, KNX TP and 2-wire MBus connections for the specific model.

Confirmed candidates1 models
  • HMI2000-ARM-E

    All serial and Ethernet acquisition protocols

    Forwarding: BACnet/IP / Modbus TCP / MQTT / Database / OPC UA

View full group specifications

The device protocol is fixed

Check each model’s listed acquisition protocols and the required host-system protocol. A model suffix alone does not establish equivalent acquisition capability.

Confirmed candidates3 models
  • HMI2000-BMS

    Listed acquisition protocols: GB/T 28181 / RTSP

    Forwarding: BACnet/IP / Modbus TCP / MQTT / OPC UA

  • HMI2000-Lite-E

    Listed acquisition protocols: Modbus TCP

    Forwarding: BACnet/IP / Modbus TCP / MQTT / OPC UA

  • HMI2000-Scada

    Listed acquisition protocols: OPC UA / OPC XML-DA / OPC DA / BACnet/IP / Modbus TCP / Siemens S7 / EtherNet/IP / SNMP

    Forwarding: BACnet/IP / Modbus TCP / MQTT / Database / OPC UA

View full group specifications

Acquisition scope needs confirmation

These models have no listed acquisition scope suitable for this decision. Check their model notes and provide device make, model and protocol documentation.

Models to verify2 models
  • HMI2000-A55

    Acquisition scope unconfirmed

    Forwarding: BACnet / Modbus / MQTT / Database / OPC UA

  • HMI2000-EMS

    Acquisition scope unconfirmed

    Forwarding: BACnet/IP / Modbus TCP / MQTT / OPC UA

View full group specifications

This guidance narrows the candidates. Confirm communication roles, read/write direction, the point list, wiring and model-specific resources before final selection.

“Unconfirmed” means documentation does not establish a value; it does not mean zero or unsupported.

Compare models in a series
ModelDevice acquisition → System forwarding
HMI2000-A55
HMI2000-ARM-E
HMI2000-BMS
HMI2000-EMS
01Acquisition scopeDevice side
—
All acquisition protocols for serial and Ethernet connections
Listed acquisition protocols
GB/T 28181RTSP
—
02Forwarding protocolsSystem side
BACnetModbusMQTTDatabase
Show 1 more
OPC UA
BACnet/IPModbus TCPMQTTDatabase
Show 1 more
OPC UA
BACnet/IPModbus TCPMQTTOPC UA
BACnet/IPModbus TCPMQTTOPC UA
Point capacity204851220482048
Ethernet ports2222
Total serial ports————
RS485————
RS232————
CAN ports————
KNX TP ports————
Two-wire MBus ports————
DI channels————
DO channels————
AI channels————
AO channels————
Touchscreen————
Model documents
Port and model notes

More than 500 protocols.

Specifications & downloads
Port and model notes

More than 500 protocols.

Specifications & downloads
Port and model notes

Converts camera streams using the GB/T 28181 and RTSP standards to HTTP. More than 500 protocols are supported.

Specifications & downloads
Port and model notes

More than 500 protocols.

Specifications & downloads
HMI2000-A55

01Acquisition scopeDevice side

—

02Forwarding protocolsSystem side

BACnetModbusMQTTDatabase
Show 1 more
OPC UA
Point capacity
2048
Ethernet ports
2
Total serial ports
—
RS485
—
RS232
—
CAN ports
—
KNX TP ports
—
Two-wire MBus ports
—
DI channels
—
DO channels
—
AI channels
—
AO channels
—
Touchscreen
—
Port and model notes

More than 500 protocols.

Specifications & downloads
HMI2000-ARM-E

01Acquisition scopeDevice side

All acquisition protocols for serial and Ethernet connections

02Forwarding protocolsSystem side

BACnet/IPModbus TCPMQTTDatabase
Show 1 more
OPC UA
Point capacity
512
Ethernet ports
2
Total serial ports
—
RS485
—
RS232
—
CAN ports
—
KNX TP ports
—
Two-wire MBus ports
—
DI channels
—
DO channels
—
AI channels
—
AO channels
—
Touchscreen
—
Port and model notes

More than 500 protocols.

Specifications & downloads
HMI2000-BMS

01Acquisition scopeDevice side

Listed acquisition protocols
GB/T 28181RTSP

02Forwarding protocolsSystem side

BACnet/IPModbus TCPMQTTOPC UA
Point capacity
2048
Ethernet ports
2
Total serial ports
—
RS485
—
RS232
—
CAN ports
—
KNX TP ports
—
Two-wire MBus ports
—
DI channels
—
DO channels
—
AI channels
—
AO channels
—
Touchscreen
—
Port and model notes

Converts camera streams using the GB/T 28181 and RTSP standards to HTTP. More than 500 protocols are supported.

Specifications & downloads
HMI2000-EMS

01Acquisition scopeDevice side

—

02Forwarding protocolsSystem side

BACnet/IPModbus TCPMQTTOPC UA
Point capacity
2048
Ethernet ports
2
Total serial ports
—
RS485
—
RS232
—
CAN ports
—
KNX TP ports
—
Two-wire MBus ports
—
DI channels
—
DO channels
—
AI channels
—
AO channels
—
Touchscreen
—
Port and model notes

More than 500 protocols.

Specifications & downloads

“—” means the documentation does not establish a value; 0 is a confirmed zero. Check model documentation for shared ports, options and protocol roles.