5 matching models · 219 in the catalog
Showing 1–4 of 5 How to choose within a series How to choose within a series Match device-side protocols and the host system first, then check ports, wireless connections and capacity. Candidates below use confirmed model specifications.
Current model group MOD1002 Acquisition Physical ports 4G and wireless Capacity
You need multiple serial and Ethernet protocols Check models confirmed to cover all acquisition protocols for serial and Ethernet connections. Check protocol scope and physical port counts separately. Confirm dedicated CAN, KNX TP and 2-wire MBus connections for the specific model.
Confirmed candidates 2 models
MOD1002-ARM ↗ All serial and Ethernet acquisition protocols
Forwarding: Modbus RTU / Modbus TCP / OPC UA
MOD1002-ARM(NXP) ↗ All serial and Ethernet acquisition protocols
Forwarding: Modbus RTU / Modbus TCP / OPC UA
View full group specifications ↗ The device protocol is fixed Check each model’s listed acquisition protocols and the required host-system protocol. A model suffix alone does not establish equivalent acquisition capability.
Confirmed candidates 2 models
MOD1002-Lite ↗ Listed acquisition protocols: Modbus / BACnet
Forwarding: Modbus RTU / Modbus TCP / OPC UA
MOD1002-Lite-E ↗ Listed acquisition protocols: Modbus RTU
Forwarding: Modbus RTU / Modbus TCP / OPC UA
View full group specifications ↗ Acquisition scope needs confirmation These models have no listed acquisition scope suitable for this decision. Check their model notes and provide device make, model and protocol documentation.
Models to verify 1 models
View full group specifications ↗ This guidance narrows the candidates. Confirm communication roles, read/write direction, the point list, wiring and model-specific resources before final selection.
“Unconfirmed” means documentation does not establish a value; it does not mean zero or unsupported.
Compare models in a series Model Device acquisition → System forwarding 01 Acquisition scopeDevice side All acquisition protocols for serial and Ethernet connections
All acquisition protocols for serial and Ethernet connections
Listed acquisition protocols Listed acquisition protocols 02 Forwarding protocolsSystem side Modbus RTU Modbus TCP OPC UA
Modbus RTU Modbus TCP OPC UA
Modbus RTU Modbus TCP OPC UA
Modbus RTU Modbus TCP OPC UA
Point capacity 512 512 512 512 Device capacity 64 64 64 64 Ethernet ports 1 1 1 1 Total serial ports 2 2 2 2 RS485 2 2 2 2 RS232 — — — — CAN ports — — — — KNX TP ports — — — — Two-wire MBus ports — — — — DI channels — — — — DO channels — — — — AI channels — — — — AO channels — — — — Touchscreen — — — — Model documents Port and model notes Supported acquisition protocols: more than 500 protocols.
Specifications & downloads ↗ Port and model notes Supported acquisition protocols: more than 500 protocols.
Specifications & downloads ↗ Specifications & downloads ↗ Specifications & downloads ↗
01 Acquisition scopeDevice side All acquisition protocols for serial and Ethernet connections
02 Forwarding protocolsSystem side Modbus RTU Modbus TCP OPC UA
Point capacity 512
Device capacity 64
Ethernet ports 1
Total serial ports 2
RS485 2 All specifications 0 means no such interface; — means the specification is unconfirmed.
Point capacity 512
Device capacity 64
Ethernet ports 1
Total serial ports 2
RS485 2
RS232 —
CAN ports —
KNX TP ports —
Two-wire MBus ports —
DI channels —
DO channels —
AI channels —
AO channels —
Touchscreen — Port and model notes Supported acquisition protocols: more than 500 protocols.
Specifications & downloads↗ 01 Acquisition scopeDevice side All acquisition protocols for serial and Ethernet connections
02 Forwarding protocolsSystem side Modbus RTU Modbus TCP OPC UA
Point capacity 512
Device capacity 64
Ethernet ports 1
Total serial ports 2
RS485 2 All specifications 0 means no such interface; — means the specification is unconfirmed.
Point capacity 512
Device capacity 64
Ethernet ports 1
Total serial ports 2
RS485 2
RS232 —
CAN ports —
KNX TP ports —
Two-wire MBus ports —
DI channels —
DO channels —
AI channels —
AO channels —
Touchscreen — Port and model notes Supported acquisition protocols: more than 500 protocols.
Specifications & downloads↗ 01 Acquisition scopeDevice side Listed acquisition protocols 02 Forwarding protocolsSystem side Modbus RTU Modbus TCP OPC UA
Point capacity 512
Device capacity 64
Ethernet ports 1
Total serial ports 2
RS485 2 All specifications 0 means no such interface; — means the specification is unconfirmed.
Point capacity 512
Device capacity 64
Ethernet ports 1
Total serial ports 2
RS485 2
RS232 —
CAN ports —
KNX TP ports —
Two-wire MBus ports —
DI channels —
DO channels —
AI channels —
AO channels —
Touchscreen — Specifications & downloads↗ 01 Acquisition scopeDevice side Listed acquisition protocols 02 Forwarding protocolsSystem side Modbus RTU Modbus TCP OPC UA
Point capacity 512
Device capacity 64
Ethernet ports 1
Total serial ports 2
RS485 2 All specifications 0 means no such interface; — means the specification is unconfirmed.
Point capacity 512
Device capacity 64
Ethernet ports 1
Total serial ports 2
RS485 2
RS232 —
CAN ports —
KNX TP ports —
Two-wire MBus ports —
DI channels —
DO channels —
AI channels —
AO channels —
Touchscreen — Specifications & downloads↗