Product overview

Integrates water, heat and other meter data into Siemens S7 systems. Configure the MBus wiring, acquisition driver and supply for the selected edition. Provides 1 Ethernet port, 1 serial port, 1 two-wire MBus port. Select the matching hardware edition below.

Key functions

Data-format processing

Supports linear scaling, bit extraction and byte-order conversion to handle different device data formats.

Scripts and triggers

Use JS scripts and triggers for required control logic alongside the configured communication points.

Point-list configuration

Configure acquisition and forwarding mappings from the field point list, then upload the project for supervisory-system access.

Typical applications

Lighting-device connectivity and management; Field-meter data integration.

Model selection essentials

  • Model configuration: 1 Ethernet port, 1 RS485 channel.
  • This model has multiple hardware editions; confirm the processor, supply and port configuration when ordering.

Native bus ports and wiring

1 Ethernet port; COM1 is 1 native two-wire MBus port (M+/M-), and COM2 is 1 RS485 serial port (A+/B-). Connect two-wire MBus to COM1 and use a 24 V supply; four-wire MBus communication wires may connect to COM2. Do not interchange these interfaces. The ordinary serial-port count is 1; MBus is counted separately. Check each power edition for its other specifications.

Wiring references (Chinese PDFs): File unavailable in this language (pp. 5, 6) / File unavailable in this language (pp. 5, 6)

Current product specifications

This model has multiple documented hardware versions. Choose the matching version below; a single specification set has not been assumed.

PFN1011-MBus — MBus to Siemens S7 gateway (standard power edition) · Chinese PDF

Current product specifications

Specifications are sourced from the supplied 2026 product catalog. Unspecified values remain unconfirmed.

ParameterSpecification
Total serial ports1
RS485 ports1
Ethernet ports1
Point capacity512
Acquisition protocolsMBus_WaterMeter / MBus_EnergyMeter_EN / MBus_EnergyMeter / Modbus RTU / Modbus TCP / DLT645-1997/2007 / Simulator
Forwarding protocolsOPC UA / S7
Physical interfacesEthernet / RS485 / MBus

Model datasheets

  • File unavailable in this language

PFN1011-MBus — MBus to Siemens S7 gateway (DC 24 V edition) · Chinese PDF

Current product specifications

Specifications are sourced from the supplied 2026 product catalog. Unspecified values remain unconfirmed.

ParameterSpecification
Total serial ports1
RS485 ports1
Ethernet ports1
Point capacity512
Acquisition protocolsMBus_WaterMeter / MBus_EnergyMeter_EN / MBus_EnergyMeter / Modbus RTU / Modbus TCP / DLT645-1997/2007 / Simulator
Forwarding protocolsOPC UA / S7
Physical interfacesEthernet / RS485 / MBus

Model datasheets

  • File unavailable in this language