Product overview

Integrates water, heat and other meter data into BACnet systems. Configure the MBus wiring, acquisition driver and supply for the selected edition. Provides 1 Ethernet port, 1 two-wire MBus port. Select the matching hardware edition below.

Key functions

COV and cross-subnet access

Supports COV subscriptions and BBMD cross-subnet access for change notifications and BACnet network integration.

BACnet alarms and events

Provides BACnet alarm and event functions for monitoring objects configured from the field point list.

Scripts and triggers

Use JS scripts and triggers for required control logic alongside the configured communication points.

Point-list configuration

Configure acquisition and forwarding mappings from the field point list, then upload the project for supervisory-system access.

Typical applications

Lighting-device connectivity and management; Field-meter data integration.

Model selection essentials

  • Model configuration: 1 Ethernet port.
  • This model has multiple hardware editions; confirm the processor, supply and port configuration when ordering.

Native bus ports and wiring

1 Ethernet port and 1 native two-wire MBus port (M+ and M-). Use a 24 V supply when connecting two-wire MBus meters. MBus terminals are not RS485 A+/B- terminals and must not be interchanged. This MBus port is separate from ordinary RS485/RS232 serial ports; undocumented ordinary serial-port quantities remain unconfirmed. Check each power edition for its other specifications.

Wiring references (Chinese PDFs): File unavailable in this language (pp. 4, 6) / File unavailable in this language (pp. 4, 6)

Current product specifications

This model has multiple documented hardware versions. Choose the matching version below; a single specification set has not been assumed.

BAC1010-MBus — MBus to BACnet gateway (standard power edition) · Chinese PDF

Current product specifications

Specifications are sourced from the supplied 2026 product catalog. Unspecified values remain unconfirmed.

ParameterSpecification
Ethernet ports1
Point capacity256
Acquisition protocolsMBus_WaterMeter / MBus_EnergyMeter_EN / MBus_EnergyMeter / Modbus TCP / DLT645-1997/2007 / Simulator
Forwarding protocolsOPC UA / BACnet/IP
Physical interfacesEthernet / MBus

Model datasheets

  • File unavailable in this language

BAC1010-MBus — MBus to BACnet gateway (DC 24 V edition) · Chinese PDF

Current product specifications

Specifications are sourced from the supplied 2026 product catalog. Unspecified values remain unconfirmed.

ParameterSpecification
Ethernet ports1
Point capacity256
Acquisition protocolsMBus_WaterMeter / MBus_EnergyMeter_EN / MBus_EnergyMeter / Modbus TCP / DLT645-1997/2007 / Simulator
Forwarding protocolsOPC UA / BACnet/IP
Physical interfacesEthernet / MBus

Model datasheets

  • File unavailable in this language