Product overview
Integrates water, heat and other meter data into MQTT systems. Configure the MBus wiring, acquisition driver and supply for the selected edition.
Selection and reading guide
- Choose the document matching the actual hardware before checking ports, power and forwarding functions; the editions are listed separately below.
Model document guide
- File unavailable in this language; purpose and functions: page 3; specification references: pages 2
- File unavailable in this language; purpose and functions: page 3; specification references: pages 2
Native bus ports and wiring
1 Ethernet port and 1 native two-wire MBus port (M+ and M-). Use a 24 V supply when connecting two-wire MBus meters. MBus terminals are not RS485 A+/B- terminals and must not be interchanged. This MBus port is separate from ordinary RS485/RS232 serial ports; undocumented ordinary serial-port quantities remain unconfirmed. Check each power edition for its other specifications.
Wiring references (Chinese PDFs): File unavailable in this language (pp. 4, 5) / File unavailable in this language (pp. 4, 5)
Current product specifications
This model has multiple documented hardware versions. Choose the matching version below; a single specification set has not been assumed.
HMI1010-MBus — MBus to MQTT gateway (standard power edition) · Chinese PDF
Current product specifications
Specifications are sourced from the supplied 2026 product catalog. Unspecified values remain unconfirmed.
| Parameter | Specification |
|---|---|
| Ethernet ports | 1 |
| Point capacity | 256 |
| Acquisition protocols | MBus_WaterMeter / MBus_EnergyMeter / MBus_EnergyMeter_EN / Modbus TCP / DLT645-1997/2007 / Simulator |
| Forwarding protocols | BACnet/IP / Modbus TCP / MQTT / OPC UA |
| Acquisition roles | Modbus TCP Client |
| Forwarding roles | BACnet/IP Server / Modbus TCP Server |
| Physical interfaces | Ethernet |
Model notes: The documentation gives inconsistent values for Forwarding protocols. These values are excluded from confirmed selection criteria.
Model datasheets
- File unavailable in this language
HMI1010-MBus — MBus to MQTT gateway (DC 24 V edition) · Chinese PDF
Current product specifications
Specifications are sourced from the supplied 2026 product catalog. Unspecified values remain unconfirmed.
| Parameter | Specification |
|---|---|
| Ethernet ports | 1 |
| Point capacity | 256 |
| Acquisition protocols | MBus_WaterMeter / MBus_EnergyMeter / MBus_EnergyMeter_EN / Modbus TCP / DLT645-1997/2007 / Simulator |
| Forwarding protocols | BACnet/IP / Modbus TCP / MQTT / OPC UA |
| Acquisition roles | Modbus TCP Client |
| Forwarding roles | BACnet/IP Server / Modbus TCP Server |
| Physical interfaces | Ethernet |
Model notes: The documentation gives inconsistent values for Forwarding protocols. These values are excluded from confirmed selection criteria.
Model datasheets