SUNFULL / PRODUCTS

Products

Find the right connection between field interfaces and system protocols.

PRODUCT FINDER

Find your connection

Select multiple protocols or enter your own. Results must meet every selected requirement.

01 / Device / acquisition protocol
Select protocols · multiple
A–Z order · Search keeps list numbers

Names are from the supplied acquisition protocol list.

Showing all 579 protocols

02 / System / forwarding protocol
Select protocols · multiple
A–Z order · Search keeps list numbers

Choose forwarding protocols or database integration. Support depends on the model documentation.

Showing all 20 protocols

Select physical interfaces separately from acquisition protocols. CAN, KNX TP and two-wire MBus ports have independent counts; protocol support does not establish a physical port. USB Type-C includes power connectors; check each model's documentation for data communication support.

DDC I/O and touchscreenRefine by product type

When a touchscreen is required, results must have a built-in touchscreen and meet all I/O counts. Otherwise, positive I/O counts select DDC controllers. Counts are minimum requirements. HMI configuration support does not imply a built-in screen.

Power and wireless connectivityAdditional requirements

Checked requirements match only confirmed capabilities. Review product notes for optional modules, shared ports and power conditions.

Filters use documented product information. Unspecified capabilities are excluded. Confirm protocol roles, device models, point counts and site conditions before ordering.

219 results

Current selection conditions

Select a condition to remove it. Multiple protocols still require an AND match.

MOD1006-ARM
Modbus gateways

MOD1006-ARM

Exposes field-device data through Modbus interfaces for PLCs, HMI software or other Modbus clients, bringing different devices into a common data interface. Provides 1 Ethernet port, 6 serial ports, 1536-point capacity. Acquisition covers more than 500 protocols; check the driver against each connected device.

RS485 ports6 portsRS232 ports—Ethernet ports1 portsSerial ports6 ports
All acquisition protocols for serial and Ethernet connectionsModbus RTUModbus TCPOPC UA
HMI1004-HDMI
Web configuration gateways

HMI1004-HDMI

Organizes field-device data into browser-based HMI screens for building or industrial monitoring and provides interfaces for other supervisory systems. Provides 1 Ethernet port, 4 serial ports, 1024-point capacity. Acquisition covers more than 500 protocols; check the driver against each connected device. The HDMI output connects an external monitor for information display.

RS485 ports4 portsRS232 ports—Ethernet ports1 portsSerial ports4 ports
HMI configurationBACnetModbusMQTT
HMI2000-ARM-E
Web configuration gateways

HMI2000-ARM-E

Organizes field-device data into browser-based HMI screens for building or industrial monitoring and provides interfaces for other supervisory systems. Provides 2 Ethernet ports, 512-point capacity. Acquisition covers more than 500 protocols; check the driver against each connected device.

RS485 ports—RS232 ports—Ethernet ports2 portsSerial ports—
HMI configurationAll acquisition protocols for serial and Ethernet connectionsBACnet/IPModbus TCPMQTTDatabase
HMI2004-A9(OPC)
Web configuration gateways

HMI2004-A9(OPC)

Organizes field-device data into browser-based HMI screens for building or industrial monitoring and provides interfaces for other supervisory systems. Provides 2 Ethernet ports, 4 serial ports, 2048-point capacity. Acquisition covers more than 500 protocols; check the driver against each connected device. This edition also supports OPC DA acquisition.

RS485 ports4 portsRS232 ports—Ethernet ports2 portsSerial ports4 ports
HMI configurationAll acquisition protocols for serial and Ethernet connectionsBACnetModbusMQTTDatabase
BAC2304-Lite
BACnet gateways

BAC2304-Lite

Converts field-controller and meter data into BACnet interfaces for point-list-based integration with building management systems. Provides 2 Ethernet ports, 4 serial ports, 1024-point capacity. Acquisition protocols: Modbus, BACnet; a Simulator driver is also included. This is a custom edition; confirm the delivery configuration against its own document.

RS485 ports4 portsRS232 ports—Ethernet ports2 portsSerial ports4 ports
Listed protocols · Simulator / Modbus / BACnetBACnet/IPBACnet MS/TPOPC UA
HMI2004-EMS-4G
Web configuration gateways

HMI2004-EMS-4G

Collects, bills, stores and classifies water, electricity, gas and heating/cooling energy data, with time-of-use electricity records and charts for reviewing building or equipment consumption. Provides 2 Ethernet ports, 4 serial ports, 2048-point capacity. Acquisition covers more than 500 protocols; check the driver against each connected device. This model supports 4G.

RS485 ports—RS232 ports—Ethernet ports2 portsSerial ports4 ports
BACnetModbusMQTT
KNX2004-ARM
KNX gateways & smart lighting modules

KNX2004-ARM

Integrates lighting and control-device data into KNX IP systems, with the documented logic and timing functions for lighting scenes. Check KNX IP and the physical KNX TP bus separately. Provides 2 Ethernet ports, 4 serial ports, 1024-point capacity. Acquisition covers more than 500 protocols; check the driver against each connected device.

RS485 ports4 portsRS232 ports—Ethernet ports2 portsSerial ports4 ports
All acquisition protocols for serial and Ethernet connectionsKNX IPOPC UA