SUNFULL / PRODUCT GUIDE

Compare models in a series

Explore model variants side by side. Compare acquisition scope, forwarding protocols and physical ports, then open a model for its full specifications and documents.

Select by requirements

15 matching models · 219 in the catalog

Showing 1–4 of 15
How to choose within a series

How to choose within a series

Match device-side protocols and the host system first, then check ports, wireless connections and capacity. Candidates below use confirmed model specifications.

Current model groupHMI1002

You need multiple serial and Ethernet protocols

Check models confirmed to cover all acquisition protocols for serial and Ethernet connections. Check protocol scope and physical port counts separately. Confirm dedicated CAN, KNX TP and 2-wire MBus connections for the specific model.

Confirmed candidates6 models
  • HMI1002-ARM

    All serial and Ethernet acquisition protocols

    Forwarding: BACnet/IP / BACnet MS/TP / Modbus / MQTT / Database / OPC UA

  • HMI1002-ARM-4G

    All serial and Ethernet acquisition protocols

    Forwarding: BACnet / Modbus / MQTT / Database / OPC UA

  • HMI1002-ARM-WiFi

    All serial and Ethernet acquisition protocols

    Forwarding: BACnet / Modbus / MQTT / Database / OPC UA

Show 3 more models
  • HMI1002-ARM(CAN)

    All serial and Ethernet acquisition protocols

    Forwarding: BACnet / Modbus / MQTT / Database / OPC UA

  • HMI1002-ARM(LoRaWAN)

    All serial and Ethernet acquisition protocols

    Forwarding: BACnet / Modbus / MQTT / Database / OPC UA

  • HMI1002-ARM(NXP)

    All serial and Ethernet acquisition protocols

    Forwarding: BACnet / Modbus / MQTT / Database / OPC UA

View full group specifications

The site uses OPC, Modbus and BACnet families

Start by checking these three families for HMI1002-Lite and the listed variants with the same scope. For other acquisition protocols, check models with the corresponding coverage.

Confirmed candidates4 models
  • HMI1002-Lite

    Acquisition families: OPC / Modbus / BACnet

    Forwarding: BACnet/IP / BACnet / Modbus / MQTT / Database / OPC UA

  • HMI1002-LITE-4G

    Acquisition families: OPC / Modbus / BACnet

    Forwarding: BACnet / Modbus / MQTT / Database / OPC UA

  • HMI1002-Lite-WiFi

    Acquisition families: OPC / Modbus / BACnet

    Forwarding: BACnet / Modbus / MQTT / Database / OPC UA

Show 1 more models
  • HMI1002-Lite(NXP)

    Acquisition families: OPC / Modbus / BACnet

    Forwarding: BACnet / Modbus / MQTT / Database / OPC UA

View full group specifications

Device-side acquisition only needs Modbus RTU

The listed HMI1002-Lite-E variants have confirmed Modbus RTU acquisition. Lite-E scope differs by series; this rule does not apply to every Lite-E model.

Confirmed candidates3 models
Continue filtering by protocol

The device protocol is fixed

Check each model’s listed acquisition protocols and the required host-system protocol. A model suffix alone does not establish equivalent acquisition capability.

Confirmed candidates1 models
  • HMI1002-KNX-TP

    Listed acquisition protocols: KNX TP

    Forwarding: Modbus / BACnet / MQTT / Database / OPC UA

View full group specifications

Acquisition scope needs confirmation

These models have no listed acquisition scope suitable for this decision. Check their model notes and provide device make, model and protocol documentation.

Models to verify1 models
View full group specifications

This guidance narrows the candidates. Confirm communication roles, read/write direction, the point list, wiring and model-specific resources before final selection.

“Unconfirmed” means documentation does not establish a value; it does not mean zero or unsupported.

Compare models in a series
ModelDevice acquisition → System forwarding
HMI1002-ARM
HMI1002-ARM-4G
HMI1002-ARM-WiFi
SUNFULL
HMI1002-ARM(CAN)
01Acquisition scopeDevice side
All acquisition protocols for serial and Ethernet connections
All acquisition protocols for serial and Ethernet connections
All acquisition protocols for serial and Ethernet connections
All acquisition protocols for serial and Ethernet connections
02Forwarding protocolsSystem side
BACnet/IPBACnet MS/TPModbusMQTT
Show 2 more
DatabaseOPC UA
BACnetModbusMQTTDatabase
Show 1 more
OPC UA
BACnetModbusMQTTDatabase
Show 1 more
OPC UA
BACnetModbusMQTTDatabase
Show 1 more
OPC UA
Point capacity512512512512
Device capacity64646464
Ethernet ports1111
Total serial ports222—
RS485222—
RS232————
CAN ports———2
KNX TP ports————
Two-wire MBus ports————
DI channels————
DO channels————
AI channels————
AO channels————
Touchscreen————
Model documents
Port and model notes

More than 500 protocols.

Specifications & downloads
Port and model notes

More than 500 protocols.

Specifications & downloads
Port and model notes

More than 500 protocols.

Specifications & downloads
Port and model notes

1 Ethernet port and 2 native CAN bus ports. CAN ports are counted separately and must not be treated as 2 RS485 serial ports. Undocumented RS485/RS232 quantities remain unconfirmed.

Specifications & downloads
HMI1002-ARM

01Acquisition scopeDevice side

All acquisition protocols for serial and Ethernet connections

02Forwarding protocolsSystem side

BACnet/IPBACnet MS/TPModbusMQTT
Show 2 more
DatabaseOPC UA
Point capacity
512
Device capacity
64
Ethernet ports
1
Total serial ports
2
RS485
2
RS232
—
CAN ports
—
KNX TP ports
—
Two-wire MBus ports
—
DI channels
—
DO channels
—
AI channels
—
AO channels
—
Touchscreen
—
Port and model notes

More than 500 protocols.

Specifications & downloads
HMI1002-ARM-4G

01Acquisition scopeDevice side

All acquisition protocols for serial and Ethernet connections

02Forwarding protocolsSystem side

BACnetModbusMQTTDatabase
Show 1 more
OPC UA
Point capacity
512
Device capacity
64
Ethernet ports
1
Total serial ports
2
RS485
2
RS232
—
CAN ports
—
KNX TP ports
—
Two-wire MBus ports
—
DI channels
—
DO channels
—
AI channels
—
AO channels
—
Touchscreen
—
Port and model notes

More than 500 protocols.

Specifications & downloads
HMI1002-ARM-WiFi

01Acquisition scopeDevice side

All acquisition protocols for serial and Ethernet connections

02Forwarding protocolsSystem side

BACnetModbusMQTTDatabase
Show 1 more
OPC UA
Point capacity
512
Device capacity
64
Ethernet ports
1
Total serial ports
2
RS485
2
RS232
—
CAN ports
—
KNX TP ports
—
Two-wire MBus ports
—
DI channels
—
DO channels
—
AI channels
—
AO channels
—
Touchscreen
—
Port and model notes

More than 500 protocols.

Specifications & downloads
SUNFULL
HMI1002-ARM(CAN)

01Acquisition scopeDevice side

All acquisition protocols for serial and Ethernet connections

02Forwarding protocolsSystem side

BACnetModbusMQTTDatabase
Show 1 more
OPC UA
Point capacity
512
Device capacity
64
Ethernet ports
1
Total serial ports
—
RS485
—
RS232
—
CAN ports
2
KNX TP ports
—
Two-wire MBus ports
—
DI channels
—
DO channels
—
AI channels
—
AO channels
—
Touchscreen
—
Port and model notes

1 Ethernet port and 2 native CAN bus ports. CAN ports are counted separately and must not be treated as 2 RS485 serial ports. Undocumented RS485/RS232 quantities remain unconfirmed.

Specifications & downloads

“—” means the documentation does not establish a value; 0 is a confirmed zero. Check model documentation for shared ports, options and protocol roles.